Fabrication and characterization of the Ti-6Al-4V/Mg scaffold

نویسندگان

  • Hossein Arabi Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Narmak, Tehran,Iran
  • Seyed Kalantari Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Narmak, Tehran,Iran
  • Seyed Mirsalehi Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Narmak, Tehran,Iran
  • Shamsodin Mirdamadi Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Narmak, Tehran,Iran
چکیده مقاله:

Ti–6Al–4V scaffolds were fabricated by powder metallurgical space holder technique in this research. The most added magnesium (Mg) powder was evaporated and a skeleton of Ti-6Al-4V alloy was produced. For this purpose Ti-6Al-4V and Mg powders mixture compacted in a steel die by applying uniaxial pressure of 500 MPa before sintering the green product in a sealed quartz tubes at 900 °C for 2 hours. Employing Archimedes’ principle and an Image Tool software, the total and open volume percent of porosities within the scaffolds were found to be in the range of 46-64% and 41-47%, respectively. Bioactivity properties of the scaffolds were investigated in a simulated body fluid (SBF). Scanning electron microscopy (SEM) and Energy dispersive spectroscopy (EDS) were used for studying the specimens’ surfaces after immersing them for 28 days. The results showed that the amounts of calcium (Ca) and phosphor (P) deposited into the porous areas were more than that of smooth surfaces due to the presence of Mg particles within the pores which provoked formation of apatite layers. Changing in the pH values of the SBF during 18 days of immersion revealed that gradual improvement in pH level due to releasing OHˉ .Using atomic absorption spectroscopy (AAS) indicated that by increasing Mg content of scaffolds, Ca concentration of SBF decreased which is an indication of apatite formation on the scaffold. Results of SBF bioactivity assays exhibited that the scaffold with 60 vol.% Mg has the best ability to induce apatite nucleation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of diamond-like carbon films deposited on commercially pure Ti and Ti–6Al–4V

The diamond-like carbon (DLC) films deposited on the articulating surface of medical-grade Ti and Ti–6Al–4V were characterized. The DLC films were synthesized by r.f. plasma assisted chemical vapor deposition (PACVD) using C6H6 at 10 mTorr. For wear tests, the ball-ondisk type wear tester was employed by wearing a 5-mm diameter ruby ball against a rotating metal disk. The DLC coating dramatical...

متن کامل

Fatigue of Ti-6Al-4V

Metallic biomaterials have essentially three fields of use; these are the artificial hip joints, screw, plates and nails for internal fixation of fractures, and dental implants. Any of these devices must support high mechanical load and resistance of material against breakage is essential. High mechanical properties are needed for structural efficiency of surgical and dental implants. But their...

متن کامل

Fabrication of TiO2 Crystalline Coatings by Combining Ti-6Al-4V Anodic Oxidation and Heat Treatments

The bio- and hemocompatibility of titanium alloys are due to the formation of a TiO2 layer. This natural oxide may have fissures which are detrimental to its properties. Anodic oxidation is used to obtain thicker films. By means of this technique, at low voltages oxidation, amorphous and low roughness coatings are obtained, while, above a certain voltage, crystalline and porous coatings are obt...

متن کامل

MICROSTRUCTURE, HARDNESS AND SURFACE ROUGHNESS CHARACTERIZATION OF EBM FABRICATED Ti-6Al-4V SAMPLES

Electron beam melting (EBM) is among the modern additive manufacturing processes whereby metal powders are selectively melted to produce very complicated components with superior mechanical properties. In this study, microstructure, hardness, and surface roughness of EBM fabricated Ti6Al4V samples were characterized. The results showed that the microstructure consisted of epitaxially-grown prim...

متن کامل

Fabrication of Porous Segments Using Ti-6Al-4V Chips for Orthopaedic Applications

Different methods have been evaluated for manufacturing the porous Ti6Al4V alloys according to decreasing stress shielding phenomenon and increasing mechanical compatibility between the metallic components and the host tissue. For this purpose, in this work Ti6Al4V alloy chips were pressed under 400 MPa pressure and then samples were categorized and heated into two groups at 1000 and 1150℃ unde...

متن کامل

Fabrication of Porous Segments Using Ti-6Al-4V Chips for Orthopaedic Applications

Different methods have been evaluated for manufacturing the porous Ti6Al4V alloys according to decreasing stress shielding phenomenon and increasing mechanical compatibility between the metallic components and the host tissue. For this purpose, in this work Ti6Al4V alloy chips were pressed under 400 MPa pressure and then samples were categorized and heated into two groups at 1000 and 1150℃ unde...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 2

صفحات  11- 24

تاریخ انتشار 2015-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023