Comparative Assessment of the Whole-cell Pertussis Vaccine Potency Using Serological and Intracerebral Mouse Protection Methods
نویسندگان
چکیده مقاله:
One of the most important QC tests of whole-cell pertussis vaccine (WCPV) is potency test. In this regard, mouse protection test (MPT) is the current potency method, which is associated with severe animal distress and large variability in results. The purpose of this study was to assess Pertussis Serological Potency Test (PSPT) as a serological alternative method to intracerebral challenge in MPT assay. In the current study, the potency of three experimental batches of WCPV (1, 2, and 3) and standard vaccine were compared using MPT and PSPT methods. In the MPT method, mice were immunized with tests and standard vaccines. After 2 weeks, they were intracerebrally challenged with Bordetella pertussis strain (18323). The potency was calculated via parallel line analysis based on the numbers of survivors 2 weeks after the challenge. Similar to MPT method, mice were immunized in the PSPT method and bled after 4 weeks. In the next step, sera were titrated by 18323-WCP-ELISA assay and potency values were estimated via parallel line analysis. Pearson correlation test was used to measure the strength of association between MPT and PSPT assay results. The potency values of the experimental laboratory batches 1, 2, and 3 in MPT assays were 11.14, 5.02, and 4.24 Iu/ml, whereas the obtained results of PSPT assays were 10.32, 4.11, and 3.06 Iu/ml, respectively. The correlation of MPT and PSPT results was 0.807. The findings of the present study demonstrated a significant correlation between MPT and PSPT results. The implementation of PSPT was more advantageous, compared to MPT due to its ethical approaches and less variability in results. The PSPT is a promising alternative method for intracerebral challenge. However, additional validation is needed to support the establishment of this method.
منابع مشابه
Comparative analysis of the intracerebral mouse protection test and serological method for potency assays of pertussis component in DTP vaccine
The aim of this study was to compare the PSPT standardized in-house as an alternative to MPT for potency assays of pertussis component. Statistical analyses have showed similar pertussis potency values when PSPT was compared to MPT. Significant correlation between the potency results obtained by in vivo and in vitro assays was also been observed. Results by PSPT have demonstrated reproducibilit...
متن کاملEvaluation of two serological methods for potency testing of whole cell pertussis vaccines.
The European Pharmacopoeia (Ph. Eur.) and the World Health Organization (WHO) require the performance of extensive quality control testing including a potency test before a vaccine batch is released for human use. Whole cell pertussis (wP) vaccine potency is assessed by a mouse protection test (MPT) based on the Kendrick test. This test compares the vaccine dose necessary to protect 50% of mice...
متن کاملPertussis Serological Potency Test as an Alternative to the Intracerebral Mouse Protection Test: Development, Evaluation and Validation.
We have developed the Pertussis Serological Potency Test (PSPT) as an alternative to potency testing of pertussis Whole Cell Vaccines (WCV) in the intracerebral Mouse Protection Test (MPT). The PSPT is based on the humoral antibody response against the whole range of B. pertussis surface-antigens per vaccine dose and correlates well with the MPT. WCV-induced-antibody responses against "protecti...
متن کاملcomparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods
هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...
15 صفحه اولassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Immunogenicity of a Triple Diphtheria-Tetanus-Whole Cell Pertussis Vaccine in Iranian Preschool Children
Background: Immunization against diphtheria, tetanus and pertussis has been applied in Iran since 1950. WHO suggests periodical evaluation of effectiveness of the triple diphtheria-tetanus-whole cell pertussis (DTwP) vaccine, worldwide. Objectives: To determine the immunogenicity of locally manufactured DTwP vaccine administered to preschool children in a number of health centers of Tehran in 2...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 74 شماره 2
صفحات 103- 109
تاریخ انتشار 2019-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023