Comparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy

author

  • Farideh Farokhi Moghadam Medical Physics Department, Faculty of Medicine & engineering, Shahid beheshti University of Medical Sciences, Tehran, Iran. Tel: +989120570453, Email: [email protected]
Abstract:

Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment techniques for parotid gland tumors using three different techniques to find the optimal technique which demonstrates sufficient target coverage and preserving of surrounding normal tissue at 3DCRT treatment of parotid cancer Materials and Methods: The CT-scans of ten parotid patients were used. The target volume and OARs were contoured and after 3D dose distribution and using of dose-volume histogram (DVH), three different plans were done and were compared: A. Ipsilateral oblique wedge photon 6MV pair with bolus B. Photons, 3-fields AP(wedge), PA(wedge), lateral(open), C. Mixed beam: 6MV photon ipsilateral oblique wedge pair & 14Mev electron with bolus (1:4) Results: Target coverage was suitable for techniques B and C. Technique c showed the best homogeneity and conformity index at target volume. The dose to OARs was lower than other techniques. On other hand, technique A demonstrated ineligible homogeneity within PTV & the higher dose to OARs than other techniques.   Conclusion: mixed beam: 6MV photon ipsilateral oblique wedge pair & 14Mev electron with bolus is an optimal treatment plan for treatment of parotid cancer patients in such way than other techniques.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Three dimensional conformal postoperative radiotherapy for unilateral parotid gland cancer: A comparison of three different parotid gland irradiation techniques

Parotid gland cancer; 3DCRT; Postoperative radiotherapy techniques; Dose distribution Abstract Introduction: Postoperative radiotherapy of the parotid gland could be achieved with various radiotherapy techniques. However they irradiate differently the surrounding organs at risk (OARs) in particular the cochlea, oral cavity & contralateral parotid causing significant increase in the risk of oral...

full text

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

full text

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

full text

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

full text

Comparison of geometric uncertainties using electronic portal imaging device in focal three-dimensional conformal radiation therapy using different head supports.

AIMS AND OBJECTIVES To study the geometric uncertainties in the treatment and evaluate the adequacy of the margins employed for planning target volume (PTV) generation in the treatment of focal conformal radiotherapy (CRT) for patients with brain tumors treated with different head support systems. MATERIALS AND METHODS The study population included 11 patients with brain tumors who were to be...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  209- 209

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023