نتایج جستجو برای: DVH

تعداد نتایج: 574  

2018
Edgar Gelover Cabel Katherine Christopher Mart Wenqing Sun Yusung Kim

The objective of this study was to assess the recommended DVH parameter (e.g., D2 cc) addition method used for combining EBRT and HDR plans, against a reference dataset generated from an EQD2-based DVH addition method. A revised DVH parameter addition method using EBRT DVH parameters derived from each patient's plan was proposed and also compared with the reference dataset. Thirty-one biopsy-pr...

Journal: :Journal of Applied Clinical Medical Physics 2018

Journal: :Medical physics 2016
M M Folkerts X Gu W Lu R J Radke S B Jiang

PURPOSE Overlapping volume histogram (OVH) and distance-to-target histogram (DTH) calculations rely on the assumption that dose gradients are symmetric with respect to primary target volume (PTV) expansion and minimum distance to PTV surface, respectively. It is desirable to lift this assumption and instead account for achievable modality-specific dose gradients (MSDG) for a given PTV shape. ...

2012
BoKyong Kim Hee Chul Park Dongryul Oh Eun Hyuk Shin Yong Chan Ahn Jinsung Kim Youngyih Han

PURPOSE To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. MATERIALS AND METHODS We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectivel...

Journal: :Medical physics 2012
Y Mao X Jia M Zarepisheh S Jiang

PURPOSE Dose-volume histogram (DVH) is a clinically relevant criterion to evaluate a treatment plan quality. It is hence desirable to incorporate DVH constraints in treatment planning process for intensity modulated radiation therapy (IMRT). Yet, these constraints usually lead to difficulties due to their non-convex nature. The purpose of this project is to solve the IMRT optimization problem w...

2010
Anil Pyakuryal W. Kenji Myint Mahesh Gopalakrishnan Sunyoung Jang Jerilyn A. Logemann Bharat B. Mittal

A Histogram Analysis in Radiation Therapy (HART) program was primarily developed to increase the efficiency and accuracy of dose-volume histogram (DVH) analysis of large quantities of patient data in radiation therapy research. The program was written in MATLAB to analyze patient plans exported from the treatment planning system (Pinnacle 3 ) in the American Association of Physicists in Medicin...

Journal: :Physics in medicine and biology 2013
M Zarepisheh M Shakourifar G Trigila P S Ghomi S Couzens A Abebe L Noreña W Shang Steve B Jiang Y Zinchenko

The dose-volume histogram (DVH) is a clinically relevant criterion to evaluate the quality of a treatment plan. It is hence desirable to incorporate DVH constraints into treatment plan optimization for intensity modulated radiation therapy. Yet, the direct inclusion of the DVH constraints into a treatment plan optimization model typically leads to great computational difficulties due to the non...

2017
David V. Fried Bhishamjit S. Chera Shiva K. Das

INTRODUCTION Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provides a tool that uses target and organ at risk (OAR) geometry to indicate the d...

Journal: :Journal of structural biology 2007
Florian Garczarek Ming Dong Dieter Typke H Ewa Witkowska Terry C Hazen Eva Nogales Mark D Biggin Robert M Glaeser

Pyruvate-ferredoxin oxidoreductatse (PFOR) carries out the central step in oxidative decarboxylation of pyruvate to acetyl-CoA. We have purified this enzyme from Desulfovibrio vulgaris Hildenborough (DvH) as part of a systematic characterization of as many multiprotein complexes as possible for this organism, and the three-dimensional structure of this enzyme has been determined by a combinatio...

2016
Michael S. Gossman

The process for validating dose-volume histogram data in brachytherapy software is presented as a supplement to a previously published article. Included is the DVH accuracy evaluation of the Best NOMOS treatment planning system called "Best TPS VolumePlan." As done previously in other software, a rectangular cuboid was contoured in the treatment planning system. A single radioactive 125I source...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید