koroush arbabi ph.d. student in medical physics, agricultural, medical & industrial research school (amirs), nuclear sciences & technology research institute (nstri), atomic energy organization of iran (aeoi), tehran, iran gholamreza raisali associate professor, nuclear engineering, radiation application research school (rars), nstri, aeoi masoomeh dehghani moghadam m.sc. in nuclear physics, deputy of nuclear research & technology, aeoi, tehran, iran mostafa ghafoori m.sc. in nuclear engineering, amirs, nstri, aeoi, tehran, iran arjang shahvar b.sc. in nuclear physics, amirs, nstri, aeoi, tehran, iran said hamidi assistant professor, nuclear physics dept., physics group, basic sciences faculty, arak university, arak, iran

introduction: well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. the chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. for the measurements, the brachytherapy sources are transferred to the middle of the tube. materials and methods: for designing the well type chamber, the measu...

Arjang Shahvar Gholamreza Raisali, Koroush Arbabi Masoomeh Dehghani Moghadam Mostafa Ghafoori Said Hamidi

Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...

A.H. Nizamani, M. Afzal, M.A. Gadhi, M.S. Akhtar, S.A. Buzdar, Sh. Fatmi,

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

Kourosh Arbabi, Zahra Saberi

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

Journal: :iranian journal of radiation research 0
m.a. gadhi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan s.a. buzdar department of physics, the islamia university of bahawalpur, pakistan m. afzal department of physics, the islamia university of bahawalpur, pakistan sh. fatmi bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan m.s. akhtar bahawalpur institute of nuclear medicine and oncology (bino) bahawalpur, pakistan a.h. nizamani department of physics, university of sind, jamshoro, hyderabad, pakistan

background: the effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted standards. secondary standard dosimetry laboratory (ssdl) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192ir . this work has been carried out to calibrate the high dose rat...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2007

پایان نامه :دانشگاه آزاد اسلامی - دانشگاه آزاد اسلامی واحد گرمسار - دانشکده علوم انسانی 1392

the purpose of this study was to investigate the effect of task repetition on accuracy of iranian efl learners ’speaking ability. in order to achieve this purpose, a null hypothesis was developed: there is no statistically significant difference between accuracy speaking ability in iranian efl learners by use of task repetition. ; of course i should mention that, beside this null hypothesis, an...

2005
A. Bridier A. Roué I. Dumas I. H. Ferreira D. Lefkopoulos

The aim of this study was to compare the high dose rate (HDR) iridium 192 source calibration in terms of reference air kerma rate with two types of ionisation chambers (a thimble chamber and a well-type chamber). Dose measurements in water have been also performed with thimble chamber and thermoluminescent dosimeters (TLD) in order to validate the absorbed dose to water calculation provided by ...

2015
Sara L. Hackett Benjamin Davis Andrew Nixon Ruth Wyatt

Constancy checks of a well-type ionization chamber should be performed regularly as part of a quality assurance regime. The goal of this work was to test the feasibility of using a linear accelerator and an orthovoltage unit to check the constancy of a well-type chamber's response to an external radiation source. The reproducibility, linearity with dose, variation with dose-rate, and variation ...