PURPOSE To compare Orbscan II and ultrasonic pachymetry for measurement of central corneal thickness (CCT) in eyes scheduled for keratorefractive surgery. METHODS CCT was measured using Orbscan II (Bausch & Lomb, USA) and then by ultrasonic pachymetry (Tomey SP-3000, Tomey Ltd, Japan) in 100 eyes of 100 patients with no history of ocular surgery scheduled for excimer laser refractive surgery....
AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...
Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...
PURPOSE To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. DESIGN Experimental study. PARTICIPANTS Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. METHODS Corneal thickness measurements were compared among the 3 me...
BACKGROUND Intraocular pressure (IOP) measurements are affected by the central cornea thickness (CCT). The conventional method for CCT measurement is ultrasonic pachymetry. However, noncontact procedures lower the risk of infection and corneal damage. In this study, we compared the CCT measured by Orbscan II, SP3000P, and ultrasonic pachymetry in patients with glaucoma or glaucoma suspect. ME...
purpose: to assess the agreement of ultrasonic pachymetry, the galilei dual scheimpflug analyzer and orbscan ii in measuring central corneal thickness (cct) in normal and keratoconic eyes. methods: in this prospective comparative study, cct was measured in 88 refractive surgery candidates and 76 (39 right) eyes of 45 keratoconic patients using ultrasonic pachymetry, galilei and orbscanii. readi...
purpose: to compare orbscan ii and ultrasonic pachymetry for measurement of central corneal thick-ness (cct) in eyes scheduled for keratorefractive surgery. methods: cct was measured using orbscan ii and then by ultrasonic pachymetry in 100 eyes of 100 patients who were scheduled for excimer laser refractive surgery. paired t-test was used for comparing the results. results: using an acoustic f...
purpose: to compare central corneal thickness (cct) measured by galilei and orbscan ii with that by ultrasonic (u/s) pachymetry in unoperated eyes. methods: cct was measured in 184 unoperated eyes of 92 healthy retractive surgery candidates using galilei, orbscan ii, and u/s pachymetry. considered as a benchmark, measurements by u/s pachymetry were compared to those obtained by the other two de...
PURPOSE To assess the agreement among ultrasonic pachymetry, the Galilei dual Scheimpflug analyzer, and Orbscan II for central and peripheral (Galilei vs. Orbscan) corneal thickness (CCT and PCT) measurement in normal and keratoconic eyes. METHODS In this prospective study, CCT and PCT were measured in 88 eyes of 88 refractive surgery candidates and 128 eyes of 69 keratoconic patients with ul...