نتایج جستجو برای: ultrasonic oscillation

تعداد نتایج: 66673  

Journal: :Journal of endodontics 1993
P J Lumley A D Walmsley R E Walton J W Rippin

This study investigated the effect of direction of file oscillation on the amount of debris and smear remaining within oval canals. Sixty-five lower premolars were allocated to six experimental groups (n = 10) and one control group (n = 5). Canals were prepared using Gates Glidden burs and hand instruments. Preparations were completed using either an ultrasonic size 15 K file or a sonic size 15...

Journal: :Journal of the Japan Society for Precision Engineering 2017

Journal: :Journal of endodontics 2010
Lei-Meng Jiang Bram Verhaagen Michel Versluis Lucas W M van der Sluis

INTRODUCTION The aims of this study were to evaluate the removal of dentin debris from the root canal by sonic or ultrasonic activation of the irrigant and the physical mechanisms of sonic activation by visualizing the oscillations of the sonic tip, both inside and outside the confinement of the root canal. METHODS Roots of 18 canines were embedded, split, and prepared into standardized root ...

2003
Vitaly Buckin Breda O ’ Driscoll

al’s properties and acoustical characteristics have been studied for a long time and ultrasonic techniques have been used in non-destructive testing and imaging for decades. Ultrasound as an analytical tool has revolutionised diagnostics in medicine, but the application of ultrasound to material’s analyses has been held back by problems with ultrasonic design, electronics, sample handling, comp...

2009
Xudong Wang Yifan Gao Yaguang Wei Zhong Lin Wang

Address correspondence to [email protected] ABSTRACT The output of an ultrasonic wave-driven nanogenerator (NG) has been found to depend on the excitation conditions and geometry. Incidence angle tests indicate that the effective area of an NG determines the amount of power that can be generated. The output power of an NG is also directly related to its distance from the ultrasonic source. A si...

2003
A. ALIZAD D. H. WHALEY J. F. GREENLEAF

oscillation of newly coming bubble is between -90 to 90 degrees. Under this condition, the radius of the aggregated bubbles is determined by the ultrasonic wave frequency and the relative phase. Based on the model, numerical analysis is carried out. The Bjerknes force over (x,y) plane is evaluated for two or more bubbles cases. The stability of a couple of aggregated bubbles is also discussed. ...

1999
Jürg Schwizer Michael Mayer Daniel Bolliger Oliver Paul Henry Baltes

A model of friction during thermosonic ball bonding is reported. It is based on recent ultrasonic stress measurements during ball bonding using piezoresistive microsensors integrated below test bonding pads. At the bonding pad, the microsensor signal is a measure for the stress caused by periodic oscillation of the capillary and gold ball. The new model interpretes the oscillation in terms of a...

Hossein Ghadiri, Zahra Khodabakhshi

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

Journal: :Journal of endodontics 2011
Lei-Meng Jiang Bram Verhaagen Michel Versluis Jelmer Langedijk Paul Wesselink Lucas W M van der Sluis

INTRODUCTION It is not clear whether increasing the ultrasonic intensity would enhance the cleaning efficacy of passive ultrasonic irrigation (PUI) inside a root canal. The aim of this study was to evaluate the effect of the ultrasonic intensity on PUI to remove dentin debris and whether there is any lateral effect beyond the ultrasonic tip. METHODS Each of 15 in vitro root canal models with ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید