نتایج جستجو برای: transmitted dosimetry

تعداد نتایج: 67391  

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak

abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia

abstract background: for treatment verification in radiation therapy. several physical characteristics of scanningliquid filled ionization chamber epid (slic-epid) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.electronic portal imaging devices (epids) have found an outstanding positionmaterials and methods: equilibrium, 1-30 mm white water mat...

E. Bezak, M. Mohammadi,

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

F Shahedi, H Gholamhosseinian M H Bahreyni M Mohammadi, M Momennezhad, R Salek, S Bayani, S M Hashemi, S Nasseri

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2010
Alessandro M Costa Gustavo L Barbi Edenyse C Bertucci Heberton Ferreira Simone Z Sansavino Beatriz Colenci Linda V E Caldas

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...

Journal: :Radiation Measurements 2022

Organized by Working Group 6 “Computational Dosimetry” of the European Radiation Dosimetry (EURADOS), a group intercomparison exercises was conducted in which participants were asked to solve predefined problems computational dosimetry. The results these comparisons published series articles this virtual special issue Measurements. This paper reviews experience gained from various and highlight...

2017
Daniel Taussky Levon Igidbashian David Donath Dominic Béliveau-Nadeauv Renée X. Larouche Yanick Hervieux Guila Delouya

PURPOSE To analyze intraoperative (IO) dosimetry using transrectal ultrasound (TRUS), performed before and after prostate low-dose-rate brachytherapy (LDR-BT), and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30). MATERIAL AND METHODS A total of 236 patients underwent prostate LDR-BT using 125I that was performed with a three-dimensional TRUS-guided interactive ...

2012
C. M. M. Paschoal M. L. Sobrinho D. do N. Souza J. Antônio Filho L. A. P. Santos

Computed tomography (CT) dosimetry normally uses an ionization chamber 100 mm long to estimate the computed tomography dose index (CTDI), however some reports have already indicated that small devices could replace the long ion chamber to improve quality assurance procedures in CT dosimetry. This paper presents a novel dosimetry system based in a commercial phototransistor evaluated for CT dosi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید