نتایج جستجو برای: transient evoked otoacoustic

تعداد نتایج: 172945  

Journal: :iranian journal of otorhinolaryngology 0
helnaz mokrian department of audiology, faculty of rehabilitation sciences, iran university of medical sciences, tehran, iran. abdolreza shaibanizadeh department of audiology, faculty of rehabilitation sciences, iran university of medical sciences, tehran, iran. saeid farahani department of audiology, faculty of rehabilitation sciences, tehran university of medical sciences, tehran, iran. shohreh jalaie department of statistics, faculty of rehabilitation sciences, tehran university of medical sciences, tehran, iran. parvane mahdi department of audiology, faculty of rehabilitation sciences, tehran university of medical sciences, tehran, iran. amin amali department of otorhinolaryngology-head and neck surgery, imam khomeini educational complex hospital, tehran university of medical sciences, tehran, iran.

introduction: tinnitus is a perception of sound without external source. the exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. the aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of distortion-product evoked otoacoustic emission (...

Journal: :acta medica iranica 0
shadman nemati department of otolaryngology- head and neck surgery, school of medicine, guilan university of medical sciences, guilan, iran. ali faghih habibi department of otolaryngology- head and neck surgery, school of medicine, guilan university of medical sciences, guilan, iran. rasool panahi department of audiology, school of rehabilitation sciences, iran university of medical sciences, tehran, iran. masoomeh pastadast department of audiology, amiralmomenin hospital, guilan university of medical sciences, guilan, iran.

while most tinnitus cases have some degree of hearing impairment, a small percent of the patients admitted to ear, nose and throat clinics or hearing evaluation centers are those who complain of tinnitus despite having normal hearing thresholds. present study was performed in order to better understanding of the probable causes of tinnitus and to investigate possible changes in the cochlear and...

2015
Giovanna Cesar Silva Camila Ribas Delecrode Adriana Tahara Kemp Fabiana Martins Ana Claudia Vieira Cardoso

Introduction The most commonly used method in neonatal hearing screening programs is transient evoked otoacoustic emissions in the first stage of the process. There are few studies comparing transient evoked otoacoustic emissions with distortion product, but some authors have investigated the issue. Objective To correlate the results of transient evoked and distortion product otoacoustic emissi...

Journal: :Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale 2003
B De Capua C De Felice D Costantini F Bagnoli D Passali

Hearing loss can be considered as the most common birth defect. Early detection of hearing loss by screening at, or shortly after, birth and appropriate intervention are critical to speech, language and cognitive development. In the present study, the characteristics of Transient Evoked Otoacoustic Emissions have been evaluated as a function of known pre- and perinatal risk factors for hearing ...

2012
Ozlem Konukseven Ilknur Di̇ncol G. Aydan Genc

healthy newborns due to its lower false-positive and referral rates, high specificity, and also its’ ability to diagnose auditory neuropathy spectrum disorder combination with Transient Evoked Otoacoustic Emissions test. On the other hand, the test time can be a disadvantage. With technological advancements, a new generation Automated Auditory Brainstem Response has been developed which is fast...

2016
Mariana Aparecida Soares Seisse Gabriela Gandolfi Sanches Carla Gentile Matas Alessandra Giannella Samelli

OBJECTIVE To determine whether there is any influence of systemic arterial hypertension on the peripheral auditory system. METHODS This was a cross-sectional study that investigated 40 individuals between 30 and 50 years old, who were divided into groups with and without systemic arterial hypertension, using data from high-frequency audiometry, transient-evoked otoacoustic emissions and disto...

Journal: :auditory and vestibular research 0
aseel al-meqbel department of hearing and speech sciences, faculty of allied health sciences, health sciences center, kuwait university, sulaibikat, kuwait hamad al-baghli department of clinical neurophysiology, ibn sina hospital, kuwait, kuwait

background and aims: this is a pilot study investigated the prevalence of hearing impairment and the impact of the known risk factors for hearing loss on infants at risk born in kuwait. methods: two hundred infants with risk of hearing impairment who met the joint committee on infants hearing (1990) criteria were screened. all newborns were included in this study if they had hospital stay for m...

برادران‌فر, محمدحسین, دادگرنیا, محمد حسین , عتیقه‌چی, سعید , علیمحمدی, سیدحسین, ملاصادقی, ابوالفضل, میروکیلی, سیدعباس , کریمی, قاسم ,

Introduction: Otoacoustic emissions are low density sounds produced from intact cochlea measureable in the presence of an intact conduction structure. The goal of this study was to assess the surgical success rate after tympanostomy tube insertion by Distortion Product Otoacoustic Emission (DPOAE) and Transient Evoked Otoacoustic Emission (TEOAE) as methods of evaluation of postoperative hearin...

Journal: :IEEE Transactions on Information Forensics and Security 2014

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید