A hybrid longitudinal-torsional ultrasonic transducer is designed and fabricated in this research. The design of the transducer was performed using the FE method with ABAQUS software, with the aim of combining the longitudinal and torsional vibration modes. The transducer horn is then fabricated using a 4-axis milling machine. The PZT stacks are employed in order to excite the transducer. The t...
A hybrid longitudinal-torsional ultrasonic transducer is designed and fabricated in this research. The design of the transducer was performed using the FE method with ABAQUS software, with the aim of combining the longitudinal and torsional vibration modes. The transducer horn is then fabricated using a 4-axis milling machine. The PZT stacks are employed in order to excite the transducer. The t...
conclusions our results indicate that changes in muscle thickness and echo intensity are induced by different inward pressures of the transducer during us. when using a technique that involves a handheld transducer, the examiner should attempt to maintain consistent inward pressure of the transducer during us, to quantify the minimal change of the rf mass and composition. results muscle thickne...
چکیده ندارد.
an extended octagonal ring (eor) transducer was designed and developed to measure forces inside the compression chamber of a large square baler in different directions. the transducer was calibrated by applying forces in three directions simultaneously and independently. the sensor revealed excellent linearity along with small cross sensitivities. horizontal and vertical primary sensitivities o...
Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...
introduction: sonophoresis has been assessed as a novel approach to create skin permeability and drug delivery using low frequencies of ultrasound waves in the range of 20 khz to 3 mhz. in this study, a system including seven 40 khz piezoelectric transducers and an insulin chamber designed by the medical physics research center has been evaluated on hyperglycemic rabbits. materials and methods:...
abstract introduction: nowadays, the advanced technology of designing electronic circuits in very small size and with very low power consumption has led to development of wearable and implantable medical devices. however, the electronic circuits need power supply that is usually provided by relatively large and heavy batteries. the discharged batteries have to replaced or recharged for long tim...
this study describes the design, construction and calibration of an adjustable three-point hitch dynamometer. the dynamometer frame design was based on an inverted u-shaped frame that was mounted between the tractor links and implement. the dynamometer frame design allows for use in both category i and ii three-point hitch systems because of its flexibility in a lower point hitch spread and mas...
this workshop features, (live) demonstration of sonographic technique of the upper extremity joints; patient positioning; transducer choices, operation and position on the anatomic landmarks; optimal evaluation of the anatomic structures in shoulder, elbow and wrist; hopefully on thursday or friday.