نتایج جستجو برای: tld dosimeter

تعداد نتایج: 2849  

2000
H. Stadtmann J. Fellinger K. J. Velbeck C. Schmitzer J. E. Rotunda E. Michler

A new extremity TLD system has been developed and tested that provides for user convenience and automated processing while meeting various accreditation requirements. The design is a result of successful collaboration among organisational entities in different countries and included research centres, users, and the manufacturer. The primary consideration was to meet the needs of the medical mar...

2009
C. Cosma T. Jurcut V. Benea M. Moldovan Alida Timar

The possibility to combine the track-etched CR-39 or Makrofol detectors with charcoal to increase the detector sensitivity was shown in the last years. Special requests are necessary in the case of a personal dosimeter when the detector must be active only during working activity. Regarding the combination of charcoal with TL detectors our preliminary investigations indicate that the TLD intens...

2007
Stephen F. Kry Michael Price David Followill Firas Mourtada Mohammad Salehpour

The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dos...

2001
Guenther Reitz Gautam Badhwar

Preliminary TLD results from the DOSMAP experiment on ISS G. Reitz, S. Deme, I. Apathy 1 German Aerospace Center (DLR), Cologne, Germany 2 KFKI Atomic Energy Research Institute, Budapest, Hungary Abstract: The Dosimetric Mapping (DOSMAP) experiment, operated by Expedition Two onboard the ISS attempted to record and map radiation inside Space Station within a four month period. One of the severa...

Journal: :International journal of radiation oncology, biology, physics 2012
J Lah D Kim S Park

PURPOSE To evaluate the suitability of the GD-301 glass dosimeter for use in in vivo dose verification in proton therapy. METHODS The glass dosimeter was analyzed for its dosimetric characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stair-like holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurement...

2015
Juha H. Koivisto Jan E. Wolff Timo Kiljunen Dirk Schulze Mika Kortesniemi

The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivit...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

2000
M. S. Kulkarni Ratna Pradeep

Personnel monitoring of more than 40,000 radiation workers in India is being carried out routinely using a Bhabha Atomic Research Centre (BARC) made thermoluminescent dosimeter (TLD) badge based on CaSO4:Dy phosphor embedded in Teflon discs [1], and a photographic film badge. Till recently the TLD badges were read using the manual type TLD badge reader system with an external interface unit for...

2015
S. J. HosseiniAliabadi S. M. Hosseini Pooya H. Afarideh F. Mianji

INTRODUCTION The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. OBJECTIVE A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...

ژورنال: سنجش و ایمنی پرتو 2015

Neutron response Induced in Thermoluminescence Dosimeter TLD-700 chips due to reactions of thermal neutrons with slab phantom and Badge Dosimeter TLD-600,700 materials in a neutron-gamma mixed field was measured. Using the linear relationship between thermal neutron fluence and the thermal neutrons induced TL response with slab phantom, Badge-TLD Materials, an empirical relationship was introdu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید