نتایج جستجو برای: tg 43 dosimetric parameters

تعداد نتایج: 690233  

2013
Mehdi Zehtabian Sedigheh Sina Reza Faghihi Ali Meigooni

In the recommendations of Task Group #43 from American Association of Physicists in Medicine (AAPM TG43), methods of brachytherapy source dosimetry are recommended, under full scattering conditions. However, in actual brachytherapy procedures, sources may not be surrounded by full scattering tissue in all directions. Clinical examples include high-dose-rate (HDR) brachytherapy of the breast or ...

2003
Keith T. Sowards Ali S. Meigooni

Purpose: Recently a new design of a 125 I brachytherapy source was introduced for interstitial seed implants, particularly for prostate seed implants. This new source is the EchoSeedTMModel 6733 125 I brachytherapy source. Due to the differences in source design and manufacturing process from one new source to the next, their dosimetric parameters should be determined according to the American ...

ayvand Taherparvar Zaynab Fardi

Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

Ali Reza Kamali-Asl Hamid Reza Hemmati Mohammad Reza Javanshir Nematollah Heidarloo, Vahid Lohrabian

Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...

Journal: :iranian journal of medical physics 0
fatemeh lotfalizadeh department of ray-medical engineering, shiraz university, shiraz, iran mehrnoosh karimipourfard department of ray-medical engineering, shiraz university, shiraz, iran bentolhoda amanat department of physics, payame noor university, tehran, iran mehdi zehtabian department of ray-medical engineering, shiraz university, shiraz, iran

introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...

2016
Julia Hofbauer Christian Kirisits Alexandra Resch Yingjie Xu Alina Sturdza Richard Pötter Nicole Nesvacil

PURPOSE To analyze the impact of heterogeneity-corrected dose calculation on dosimetric quality parameters in gynecological and breast brachytherapy using Acuros, a grid-based Boltzmann equation solver (GBBS), and to evaluate the shielding effects of different cervix brachytherapy applicators. MATERIAL AND METHODS Calculations with TG-43 and Acuros were based on computed tomography (CT) retro...

Journal: :iranian journal of medical physics 0
sanaz hariri tabrizi ph.d. student of radiation medicine engineering, , shahid beheshti university, tehran, iran alireza kamali asl assistant professor,radiation medicine engineering., shahid beheshti university, tehran, iran zohreh azma ph.d. student of radiation medicine engineering, , shahid beheshti university, tehran, iran

introduction: brachytherapy is one of the most common treatment modalities for gynecological cancer. the gzp6 brachytherapy system is one of the devices utilized in iran. it has been considered particularly due to its low cost compared to other more complete and established systems. this system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید