نتایج جستجو برای: stiffness degrading material

تعداد نتایج: 419137  

2013
Chia-Ying LIN ChengYu LIN Scott J. HOLLISTER

The current study proposed a topology optimization method accounting for base material degradation and create a degradable device that retains sufficient stiffness through the degradation process to provide load bearings for tissue regeneration in orthopaedic applications. Degradable materials are less stiff than permanent materials and suffer further stiffness reduction through time when consi...

2005
S. Torquato A. Donev A. G. Evans C. J. Brinker

The drive toward increased semiconductor device densities and improved performance has set in motion the search for low-dielectric-constant materials. While introducing porosity in silica holds promise for reducing the dielectric constant, it remains elusive how to accomplish this without seriously degrading the thermomechanical performance. This article demonstrates a contemporary protocol for...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان 1390

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

Journal: :Tissue engineering 2007
Tanyarut Boontheekul Elliott E Hill Hyun-Joon Kong David J Mooney

Mechanical stiffness and degradability are important material parameters in tissue engineering. The aim of this study was to address the hypothesis that these variables regulate the function of myoblasts cultured in 2-D and 3-D microenvironments. Development of cell-interactive alginate gels with tunable degradation rates and mechanical stiffness was established by a combination of partial oxid...

G. Yousefi M. Akhondizadeh, M. Fooladi Mahani

Deformation of the silo wall due to the single ball impact is modeled in ANSYS. The material in silo, as a Winkler bed, is replaced by spring-damper elements and the spring stiffness and damper coefficients are evaluated of the granular material and wall properties. The granular material deformation under the specified force is measured to evaluate the granular stiffness to be used for determin...

2008
Peter Grassl

The modeling of statistical size effect of concrete structures that fail at crack initiation is studied, with special attention to the interaction between the autocorrelation length and the size of the failure zone. The mechanical failure of concrete is modeled by a network of axial springs with degrading stiffness. The heterogeneity of concrete is idealized by spatial variation of the tensile ...

2005
M. N. Kozicki C. L. Brown M. Mitkova S. Enderling J. Hedley A. J. Walton

This paper reports on Ag-Ge-Se solid electrolyte films which can support the rapid net displacement of metal mass from a silver source to a target location within a MEMS device at low voltage and current. This displacement of mass can be used to alter material parameters and we have demonstrated a tunable MEMS resonator using this principle. In this application, the electrodeposited mass is mad...

2013
Oliver Winter Hannes Lacher Christian Kral

Temperature degrading of magnet material is of mayor interest in many applications. Segmented rare earth Halbach arrays are subject to an augmented temperature degrading effect due to local demagnetisation. This paper presents results using a parameter-based material demagnetisation model. Measurement results of high temperature Halbach arrays are validated with 2D FEA.

Journal: :Journal of The Royal Society Interface 2019

Journal: :Acta of bioengineering and biomechanics 2016
Agnieszka Tomaszewska

PURPOSE There is a discussion in literature concerning mechanical properties and modelling of surgical meshes. An important feature of elastic modulus dependency on load history is taken into account in this paper, as implants are subjected to variable loading during human activity. The example of DynaMesh®-IPOM surgical implant is studied. METHODS The analysis is based on failure tension tes...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید