نتایج جستجو برای: stapes teflon piston

تعداد نتایج: 7026  

Journal: :apadana journal of clinical research 2013
nader saki soheila nikakhlagh fakher rahim

background & objectives: the aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   materials & methods: in this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in imam khomeini and apadana hospitals of ahva...

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...

2015
Soheila Nikakhlagh Nader Saki Fakher Rahim

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis. Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were rev...

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

Journal: :iranian journal of otorhinolaryngology 0
mohammad faramarzi otolaryngology research center, shiraz university of medical sciences, shiraz, iran. nafiseh gilanifar otolaryngology research center, shiraz university of medical sciences, shiraz, iran. sareh roosta otolaryngology research center, shiraz university of medical sciences, shiraz, iran.

introduction:different types of prosthesis are available for stapes replacement. because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic causse loop teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.materials and methods:a total of 57 ears were included in ...

Journal: :Otolaryngologia polska = The Polish otolaryngology 2008
Marcin Durko Tomasz Durko Anna Pajor Ramzes Stańczyk Wioletta Pietruszewska Katarzyna Starska Andrzej Jankowski

AIM Analysis of indications for stapes revision surgery in patients qualified for the secondary procedure at the Otosurgery Dept. Medical University of Lodz. MATERIAL AND METHODS 25 cases of stapes revision surgery out of the 385 total treated surgically otosclerosis cases are discussed. RESULTS In group A (patients after total stapedectomy) the following indications for the secondary surgi...

2017
Mohammad Faramarzi Nafiseh Gilanifar Sareh Roosta

INTRODUCTION Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis. MATERIALS AND METHODS A total of 57 ears were included ...

Journal: :Advances in oto-rhino-laryngology 2007
Wolfgang Arnold Elefterios Ferekidis Karl-Friedrich Hamann

In a prospective study, 165 total stapedectomies and 152 small fenestra stapedotomies were performed by three experienced surgeons between 2001 and 2003. In total stapedectomy, a self-made Schuknecht steel wire connective tissue prosthesis, and in stapedotomy, a 0.6-mm platinum wire Teflon piston was used. The pre- and postoperative bone conduction thresholds were compared at the frequencies 25...

Journal: :Hearing research 2012
Albrecht Eiber Alexander M Huber Michael Lauxmann Michail Chatzimichalis Damien Sequeira Jae Hoon Sim

Classic theories of hearing have considered only a translational component (piston-like component) of the stapes motion as being the effective stimulus for cochlear activation and thus the sensation of hearing. Our previous study (Huber et al., 2008) qualitatively showed that rotational components around the long and short axes of the footplate (rocking-like components) lead to cochlear activat...

2016
B. Sergi G. Paludetti

Over the last 20 years, the number of stapes operations performed has decreased steadily. This inadequate exposure to stapes surgery poses problems for both trainees and trainers. We retrospectively reviewed the outcomes of stapedotomy performed by a young physician at the ENT Clinic of the "A. Gemelli" Hospital of Rome. We used the technique of "one-shot" CO2 Laser stapedotomy using a titanium...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید