نتایج جستجو برای: srk t

تعداد نتایج: 703436  

2000
Mohammad-Ali Javadi Sepehr Feizi Parviz Malekifar

PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...

2017
Hasan Razmjoo Hosein Atarzadeh Neda Kargar Mohammad Behfarnia Kobra Nasrollahi Ali Kamali

BACKGROUND To compare refractive index variation between Hoffer-Q, Haigis and SRK/T formulas used for preoperative biometry calculation in patients with axial length >25 mm, undergoing cataract surgery. MATERIALS AND METHODS This is a randomized clinical trial study was performed on 54 eyes of 54 patients with ages of 40-70 years old and axial length >25 mm classified into three groups that t...

2009
Seung Mo Kim Joohyun Choi Sangkyung Choi

PURPOSE To evaluate the refractive predictability of a partial coherence interferometry (PCI) biometry device (IOL Master) for cataract surgery and to investigate factors that may affect it. METHODS Retrospective review of 209 eyes from 151 patients that had undergone preoperative PCI biometry and an uneventful phacoemulsification cataract surgery with posterior chamber intraocular lens (IOL)...

Journal: :Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH 2014
P Joshi R Mehta Suma Ganesh

INTRODUCTION Selection of an appropriately-powered IOL is a complex issue, especially in eyes with an axial length of less than 20 mm in pediatric cataract. OBJECTIVE To assess the accuracy of IOL power calculation formulae in pediatric cataracts in eyes with an axial length of less than 20 mm. MATERIALS AND METHODS The records of children less than 15 years old with congenital cataract who...

2011
Young Rae Roh Sang Mok Lee Young Keun Han Mee Kum Kim Won Ryang Wee Jin Hak Lee

PURPOSE To evaluate the predictability of intraocular lens (IOL) power calculations using the IOLMaster and four different IOL power calculation formulas (Haigis, Hoffer Q, SRK II, and SRK/T) for cataract surgery in eyes with a short axial length (AL). METHODS The present study was a retrospective comparative analysis which included 25 eyes with an AL shorter than 22.0 mm that underwent uneve...

2018
Mohammad Ghoreyshi Ahmadreza Khalilian Mohammadreza Peyman Mohaddeseh Mohammadinia Alireza Peyman

Purpose To compare the performance of OKULIX ray-tracing software with SRK-T and Hoffer Q formula in intraocular lens (IOL) power calculation in patients presenting with cataract. Methods In this prospective study, 104 eyes of 104 patients with cataract who underwent phacoemulsification and IOL implantation were recruited. Three IOL brands were used and for all eyes, IOL power calculation was...

Journal: :Archives of ophthalmology 1997
Monica T P Odenthal Cathrien A Eggink Gerrit Melles Jan H Pameyer Annette J M Geerards W Houdijn Beekhuis

OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...

Journal: :journal of current ophthalmology 0
سیدمحمدرضا طاهری seyed mohammad reza taheri آزیتا خیلتاش azita kheiltash حسن هاشمی hassan hashemi

purpose : to evaluate the accuracy of the two methods the clinical history method (chm), and the contact lens method (clm), in refractive corneal power determination and comparing the accuracy of srk ii, srk t and holladay ii (h ii) formulas for intraocular lens (iol) power calculation in patients who had laser in situ keratomileusis (lasik) surgery for myopia with or without astigmatism method...

Journal: :American journal of ophthalmology 2013
Deborah K Vanderveen Rupal H Trivedi Azhar Nizam Michael J Lynn Scott R Lambert

PURPOSE To compare accuracy of intraocular lens (IOL) power calculation formulae in infantile eyes with primary IOL implantation. DESIGN Comparative case series. METHODS The Hoffer Q, Holladay 1, Holladay 2, Sanders-Retzlaff-Kraff (SRK) II, and Sanders-Retzlaff-Kraff theoretic (SRK/T) formulae were used to calculate predicted postoperative refraction for eyes that received primary IOL impla...

Journal: :The Open Ophthalmology Journal 2021

Introduction: This study aimed to evaluate the differences in Intraocular Lens (IOL) power keratoconus (KC) eyes between calculations obtained clinically with most commonly used formulas healthy (SRK T, Holladay 1, Hoffer Q and Haigis) as well define predictive factors for such differences. Methods: retrospective comprised 43 of 22 patients no previous ocular surgery. IOL powers were calculated...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید