نتایج جستجو برای: spin cut off parameter
تعداد نتایج: 557386 فیلتر نتایج به سال:
Nuclear level densities and spin cut-off factors have been deduced for nuclei in the mass region 24‹A‹63,from a microscopic theory, which includes nuclear pairing interaction. Single particle levels for both Seeger and Nilsson potentials were used in the calcdations. Level densities extracted from the theory are compared with their conesponding experimental values, It is found that the overall...
nuclear level densities and spin cut-off factors have been deduced for nuclei in the mass region 24‹a‹63,from a microscopic theory, which includes nuclear pairing interaction. single particle levels for both seeger and nilsson potentials were used in the calcdations. level densities extracted from the theory are compared with their conesponding experimental values, it is found that the overall ...
چکیده ندارد.
On the bases of Bethe and the constant temperature models, the level density parameters have been calculated for the 36Cl, 40K, 60Co and 61Ni nuclei, nucleuses through fitting the complete level schemes in low excitation energy levels. Both calculations reproduce experimental level densities equally well. Th...
Objectives : The study goal was to investigate the effectiveness of anxiety-regulating short-term dynamic psychotherapy (STDP) in the treatment of male patients with social phobia. Method: The study was carried out over six young men with social phobia who were selected using purposeful sampling method, as a multiple baseline experimental single case study framework design, and 20 sessions fo...
background: we investigated whether the lungheart ratio parameter (lhr) can be used to identify the optimum cut off frequency for butterworth filter in 99mtc myocardial spect imaging. materials and methods: this study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μci/ml (0.148 mbq/ml) 99mtc c...
Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...
2014 The electron spin-lattice relaxation time T1 of V4+ in amorphous V2O5 has been measured in the X-band between 1.4 K and 100 K : T1-1 = 39 T2 $$ ~056/T x dx sinh x We explain this behaviour using a process requiring one two-level system (T.L.S.) modulating the crystal field, and one phonon. The characteristic temperature 56 K must be associated not with the maximum energy of the T.L.S. but ...
maximizing economic earnings is the most common goal in cut-off grade optimization of open-pit mining operations. when this is the case, the price of the product has a critical effect on optimum value of cut-off grade. this paper investigates the relationship between optimum cut-off grade and price to maximize total cash flow and net percent value (npv) of operation. in order to visualize this ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید