Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 2008
Rosemary Ouseph Colin A Hutchison Richard A Ward

BACKGROUND Membranes fabricated from nominally similar polymers may be markedly different in chemical composition, morphology and geometry. To examine the relative importance of these factors to dialyzer performance, the removal of small and large uraemic toxins was determined for dialyzers containing 'polysulfone' membranes of different composition and morphology, with and without fibre undula...

Journal: :Blood purification 2013
Jeong Chul Kim Dinna Cruz Francesco Garzotto Manish Kaushik Catarina Teixeria Marie Baldwin Ian Baldwin Federico Nalesso Ji Hyun Kim Eungtaek Kang Hee Chan Kim Claudio Ronco

BACKGROUND/AIMS Continuous renal replacement therapy (CRRT) is commonly used for critically ill patients with acute kidney injury. During treatment, a slow dialysate flow rate can be applied to enhance diffusive solute removal. However, due to the lack of the rationale of the dialysate flow configuration (countercurrent or concurrent to blood flow), in clinical practice, the connection settings...

Journal: :Journal of Japanese Society for Dialysis Therapy 1983

Journal: :JAPANES JOURNAL OF MEDICAL INSTRUMENTATION 1993

2015
Sunny Eloot Wim Van Biesen Mette Axelsen Griet Glorieux Robert Smith Pedersen James Goya Heaf

BACKGROUND Multipass hemodialysis (MPHD) is a recently described dialysis modality, involving the use of small volumes of dialysate which are repetitively recycled. Dialysis regimes of 8 hours for six days a week using this device result in an increased removal of small water soluble solutes and middle molecules compared to standard hemodialysis (SHD). Since protein-bound solutes (PBS) exert im...

The aim of this study was to evaluate the adsorption capacity of the novel coated activated carbon by chitosan for removal of Cr (VI) and Cd (II) ions from single and bi-solute dilute aqueous solutions. In addition, the adsorption abilities of activated carbon (AC), chitosan (CH) and chitosan / activated carbon composite (CHAC) have been compared. Adsorption studies were performed in a batch sy...

Journal: :JOURNAL OF CHEMICAL ENGINEERING OF JAPAN 1983

Journal: :Journal of the American Society of Nephrology : JASN 2000
R A Ward B Schmidt J Hullin G F Hillebrand W Samtleben

Some of the morbidity associated with chronic hemodialysis is thought to result from retention of large molecular weight solutes that are poorly removed by diffusion in conventional hemodialysis. Hemodiafiltration combines convective and diffusive solute removal in a single therapy. The hypothesis that hemodiafiltration provides better solute removal than high-flux hemodialysis was tested in a ...

Journal: :Advances in peritoneal dialysis. Conference on Peritoneal Dialysis 2006
Hitoshi Hoshi Hidetomo Nakamoto Yoshihiko Kanno Hiroshi Takane Naofumi Ikeda Soichi Sugahara Hirokazu Okada Hiromichi Suzuki

Continuous ambulatory peritoneal dialysis (CAPD) and hemodialysis (HD) both have advantages in the treatment of patients with renal failure. In CAPD, solute removal is sometimes insufficient in patients who have a relatively large muscle mass that produces high levels of creatinine. To compensate for this deficiency, frequent exchanges and large dialysate volumes are required. We previously rep...