نتایج جستجو برای: silorane

تعداد نتایج: 306  

2015
Narmin Mohammadi Mahmoud Bahari Soodabeh Kimyai Behnam Rahbani Nobar

OBJECTIVES Composite repair is a minimally invasive and conservative approach. This study aimed to evaluate the effect of an additional hydrophobic resin layer on the repair shear bond strength of a silorane-based composite repaired with silorane or methacrylate-based composite. MATERIALS AND METHODS Sixty bar-shaped composite blocks were fabricated and stored in saline for 72 hours. The surf...

2015
Laura Alves Bastos Ana Beatriz Silva Sousa Brahim Drubi-Filho Fernanda de Carvalho Panzeri Pires-de-Souza Lucas da Fonseca Roberti Garcia

OBJECTIVES The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. MATERIALS AND METHODS Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesiv...

2012
Janaina Bechtold Priscila Jaques dos Santos Andrea Anido-Anido Vinícius Di Hipólito Roberta Caroline Bruschi Alonso Paulo Henrique Perlatti D’Alpino

OBJECTIVES To evaluate the influence of various photoactivation techniques on the internal gap, Knoop-hardness, and polymerization depth of silorane- and methacrylate-based composites in Class II restorations. METHODS Preparations were made in third molars (n = 10), according to composites (Filtek P60: methacrylate; Filtek P90: silorane) and photoactivation techniques (OC: occlusal photoactiv...

2013
Suat Ozcan Ihsan Yikilgan Mine Betul Uctasli Oya Bala Zeliha Gonca Bek Kurklu

OBJECTIVE The aim of this study was to evaluate the change in surface hardness of silorane-based composite resin (Filtek Silorane) in time and compare the results with the surface hardness of two methacrylate-based resins (Filtek Supreme and Majesty Posterior). MATERIALS AND METHODS From each composite material, 18 wheel-shaped samples (5-mm diameter and 2-mm depth) were prepared. Top and bot...

2011
Motaz A. Ghulman

Aim. To investigate the effect of C factor on marginal adaptation of low-shrinking composite (Silorane).The null hypothesis was that the marginal adaptation of "Silorane" is not affected by the cavity configuration. Materials and Methods. A Silorane based and a methacrylate based composites, with their corresponding self-etch adhesive systems "Filtek Silorane/Silorane Adhesive Bond System and F...

Journal: :Dental materials journal 2012
Aromi Kang Sung-Ae Son Bock Hur Young Hoon Kwon Jung Hoon Ro Jeong-Kil Park

The purpose of this study were to evaluate the discoloration of a silorane-based resin and two methacrylated-based resin composites upon exposure to different staining solutions coffee, red wine, porcine liver esterase and distilled water for 7 days. The colors of all specimens before and after storage in the solutions were measured by a spectrophotometer based on CIE Lab system, and the color ...

Journal: :General dentistry 2013
Christopher S Nuttall Kraig S Vandewalle Jeffery A Casey Kent A Sabey

This study evaluated the shear-bond strength of a resin-modified glass ionomer (RMGI) restorative material to a new silorane-based composite and a methacrylate-based composite in a sandwich technique with various combinations of surface treatments and bonding agents. Two composites, 2 bonding agents and 4 surface preparations were used to create 16 groups with 10 specimens each. After 24 hours ...

2015
Fernanda Oliveira CHAVES Natália Coelho de FARIAS Luciano Marcelo de Mello MEDEIROS Roberta Caroline Bruschi ALONSO Vinicius DI HIPÓLITO Paulo Henrique Perlatti D'ALPINO

OBJECTIVE To investigate the mechanical properties of different classifications of composites indicated for posterior application as functions of the storage condition and of the energy dose. MATERIAL AND METHODS Specimens (8 x 2 x 2 mm) were obtained according to the factors: I) Composites (3M ESPE): Filtek P60, Filtek Z350XT, and Filtek Silorane; II) Syringe storage conditions: room tempera...

2016
Narmin Mohammadi Elmira Jafari-Navimipour Soodabeh Kimyai Amir-Ahmad Ajami Mahmoud Bahari Mohammad Ansarin Mahsa Ansarin

BACKGROUND The use of composites in dental restoration has been commonly criticized, due to their underwhelming mechanical properties. This problem may be solved partially by preheating. The present research aims to determine the effect of preheating on the mechanical properties of two different classes of composites. MATERIAL AND METHODS A Silorane-based (Silorane) and a Methacrylate-based (...

2016
Sharifi M Khoramian Tusi S

STATEMENT OF PROBLEM The bond strength between restorative material and tooth structure is so important for conduction of durable restoration. Considering the recent attention to low shrinkage composite resins, evaluation of micro tensile bond strength of these materials would be valuable. OBJECTIVES To compare the microtensile bond strength of silorane composite resin (Filtek P90) with the c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید