نتایج جستجو برای: silicone tube
تعداد نتایج: 105554 فیلتر نتایج به سال:
khataminia g, md*; keramati ag, md ahvaz jondi shapoor university of medical sciences, ahvaz, iran *corresponding author: [email protected] purpose: to report the demographics and clinical profile, and outcomes of canalicular laceration repaired with mini monoka monocanalicular stent. method: all patients who had undergone canalicular laceration repair over 4 years (2004-2008) at imam khom...
purpose: to evaluate the outcomes of traumatic canalicular laceration repair using masterka silicone tube. methods: this interventional case series included 25 patients with traumatic canalicular laceration who underwent canalicular repair with masterka tube. the patients were followed at least for 6 months. at last visit, anatomic and functional successes were assessed by diagnostic probing an...
purpose : to report a case of retained silicone tube case report : we report a case of 48-year-old iranian lady who referred to the department of otolaryngology with 18 years history of epiphora and intermittent mucopurulant discharge from the left lacrimal canaliculi. she had external dacryocystorhinostomy (dcr) with silicon stenting for epiphora 18 years ago but epiphora had continued after s...
Tracheal stenosis or tracheal injury is a distressing condition. The silicone tracheal T-tube presents a substitute for stent of this complicated disease. We have come across a case of tracheal perforation in which tracheoplasty was planned. After traceoplasty silicone tracheal T-tube was placed as a stent. We were not able to connect silicone tracheal T-tube with Bain circuit with ET TUBE No. ...
BACKGROUND This study aimed to investigate the efficacy and safety of 3 nasal packing products (silicone tube, Beschitin-F, and Aquacel1-Ag) after functional endoscopic sinus surgery (FESS) for chronic rhinosinusitis (CRS) patients in China. MATERIAL AND METHODS Sixty-six CRS patients undergoing FESS surgery were randomly divided into 3 groups (22 patients in each group): the silicone tube grou...
Silicone oil use as an adjunct to complicated vitreoretinal surgery is becoming more frequent. Refractory glaucoma in these patients is common. Isolated reports have mentioned the possibility of silicone oil migrating and/or obstructing the tube in the anterior chamber of Molteno implants (IOP, Costa Mesa, Calif). This report describes a case of intraocular silicone oil egressing through an Ahm...
PURPOSE To evaluate prognostic factors affecting silicone tube intubation outcomes in Asian patients with lacrimal drainage system stenosis. METHODS A retrospective review was conducted on the medical records of 822 patients (1,118 eyes) who had undergone silicone tube intubation to treat lacrimal drainage system stenosis between January 2011 and December 2012. Patients were divided into two ...
A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the...
a dissolved methane sensor based on silicone tube was designed, constructed and optimized.the silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.a continuous stream of helium (50 ml/min) was directed through the tubing, sweeping out the dissolved methane which diffused through the walls of the tubing from t...
Abstract. We describe the model and construction of a two-flow (or divided-flow) humidity generator, developed at LNE-Cnam, that uses mass flow controllers to mix stream dry gas with humid saturated 28 ∘C. It can generate wide range humidity, mole fractions in 0.7×10-6<x<9000×10-6, without using low temperature or high pressure. This is suitable for calibrating balloon-borne instruments m...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید