s. mohammadi h. r. mosaddegh m. yousefian

this paper presents a novel control approach used in shunt active power filter based on variable structure control combined with random pwm technique (rvsc) that provides robust, fast, and more favorable performance for active power filter. this control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

Journal: :journal of artificial intelligence in electrical engineering 0

this paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (sapfs). this method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. next, the amplitude of the reference mains currentis computed with ...

H. R. Mosaddegh M. Yousefian S. Mohammadi

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

In this paper, a novel control strategy for a Shunt Active Power Filter (shunt-APF) is proposed. In the proposed control strategy which is based on a new application of the instantaneous reactive power theory, the current injected by the shunt-APF is capable of compensation for the reactive component, the harmonic components and also unbalance of the load current. In this strategy, the shunt-AP...

2012
B. Jyothi Jyothsna Rani Gopal Rao

This paper deals with a three-phase unified power quality conditioner (UPQC), with a combination of shunt active power filter and series active power filter is used to eliminate supply current harmonics, compensate reactive power, voltage sag and voltage swell compensation on distribution network. The performance of the active power filter mainly depends on control strategy used to generate ref...

2014
Shiuly Mukherjee Nitin Saxena A K Sharma

This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...

2014
K.S.S. Prasad

This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...

منفرد, محمد, موحدی تبار, علی,

This paper presents a new approach for single-phase shunt active power filter with LCL output filter based on the two-loop control theory. In this method unlike the conventional two loop control, internal loop stability theorem with considering delay effect is studied. Moreover, an observer based on the Kalman-filter is combined with the proposed control scheme, to reducing the numbers of power...

2013
Rejil Chandran

A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...