In this research in-plane shear Behavior of composite steel-concrete shear walls was investigated considering the Effects of steel plates thickness, spaces between shear studs, shape and type of shear studs and existing of minimum reinforcement in wall section. Several finite element models were analyzed and Numerical results of two models were taken under verification with existent experimenta...
A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedd...
The behavior of corroded steel–concrete composite beams under hogging moment was studied by experimental investigation and theoretical analysis. A total of eight specimens, six of which had corroded shear studs, were tested. The corrosion rate of studs ranged from 0 to approximately 50%. The constant-current accelerated corrosion method was adopted to accelerate the corrosion process. The loadi...
The strength of sheathed wall systems is substantially greater than unsheathed walls with the same studs. Testing on studs sheathed on both sides with dry gypsum board demonstrate strength increases as large as 70% over unsheathed studs (Miller and Peköz 1993, Miller and Peköz 1994). The current AISI Specification for sheathed wall stud systems are complicated, only apply when the sheathing is ...
Three types of shear stud arrangement, respectively featuring an orthogonal, a radial and a critical perimeter pattern, were evaluated numerically. A numerical investigation was conducted using the finite element software ABAQUS to evaluate their ability to resist punching shear in a flat plate. The finite element analysis here is an application of the nonlinear analysis of reinforced concrete ...
In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...
Cold-formed steel (CFS) shear walls with concrete-filled rectangular steel tube (CFRST) columns as end studs can upgrade the performance of mid-rise CFS structures, such as the vertical bearing capacity, anti-overturning ability, shear strength, and fire resistance properties, thereby enhancing the safety of structures. A theoretical hysteretic model is established according to a previous exper...