نتایج جستجو برای: seismic isolation systems

تعداد نتایج: 1336582  

Journal: :international journal of civil engineering 0
a. komak panah department of civil engineering, faculty of engineering tarbiat modares university, p.o. box 14155-4838 tehran, iran a.h. khoshay department of civil engineering, faculty of engineering tarbiat modares university, p.o. box 14155-4838 tehran, iran

to increase the safety of structures against strong ground motions and their life due to environmental issues on the earth and saving in terms of materials, it is necessary to expand and upgrade seismic resistant systems. however, more cost-effective systems which have sufficient influence on the seismic performance of structures and also more compatibility with the regional conditions, will be...

Seismic isolation is a method to reduce the destructive effects of earthquakes on a structure in which the structure is separated from its foundation by devices called seismic isolators. As a result, the horizontal movements of the earthquake transmitted to the structure are reduced. The seismic isolation is used for both newly constructed structures as well as for retrofitting the existing bui...

In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...

2014
Peter Cooper

Within the past decade, seismic isolation systems have gained rapid popularity in the earthquake resistant design of bridge structures. This popularity has come in response to the inadequacy of earlier seismic design and retrofit methodologies. The mechanical shortcomings and subsequent failure mechanisms associated with the early elastic seismic design philosophy are first presented, followed ...

Journal: :civil engineering infrastructures journal 0
shaghayegh alvandi m.sc., student, school of civil engineering, college of engineering, university of tehran, p.o. box: 11155-4563, tehran, iran. mehdi ghassemieh associate professor, school of civil engineering, college of engineering, university of tehran, p.o. box: 11155-4563, tehran, iran.

in the last two decades, there has been an increasing interest in structural engineering control methods. shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...

Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...

2012
George C. Lee

In earthquake resistance design of structures, two general concepts have been used. The first is to increase the capacity of the structures to resist the earthquake load effects (mostly horizontal forces) or to increase the dynamic stiffness such as the seismic energy dissipation ability by adding damping systems (both devices and/or structural fuses). The second concept includes seismic isolat...

F. Rahimzadeh Rofooei and H. Saadatnia,

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

F. Rahimzadeh Rofooei and H. Saadatnia,

The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...

2016
Masaki Taniguchi Kohei Fujita Masaaki Tsuji Izuru Takewaki

An innovative hybrid control building system of multiple isolation and connection is proposed and investigated using both time history and input energy responses for various types of ground motions together with transfer functions. It is concerned that the seismic displacement response at the base-isolation layer of the existing baseisolated buildings may extremely increase under long-period an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید