نتایج جستجو برای: screw penetration

تعداد نتایج: 51647  

2018
Yunus Oc Bekir Eray Kilinc Anıl Gulcu Ali Varol Rodi Ertugrul Adnan Kara

BACKGROUND Complications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography in the evaluation of dorsal cortex screw penetration following volar plate fixation. METHODS We recruited 47 patients (33 males, 14 females, mean age 37.4 years; range...

2001

Introduction: Anterior spinal instrumentation of the thoracic and lumbar spine has gained in popularity since Dwyer et al [1] developed the cable system in 1964. However, implant loosening, screw breakage and cut-throughs have been noted clinically when using Dwyer or Zielke's Ventrale Derotations Spondylodese (VDS) instrumentations [2,3]. To avoid these complications and pseudarthrosis, one ma...

2017
Qiuke Wang Yu Zhu Yifei Liu Lei Wang Yunfeng Chen

OBJECTIVES In this study, we investigated the correlation between fracture classification and secondary screw penetration. METHODS We retrospectively identified 189 patients with displaced proximal humeral fractures treated by ORIF at our hospital between June 2006 and June 2013. All fractures were classified radiographically before surgery and follow-up for least 2 years after surgery was re...

Journal: :archives of trauma research 0
sascha rausch trauma department, jena university hospital, jena, germany; trauma department, jena university hospital, jena, germany. tel: +49-36419322889, fax: +49-36419322802 ivan marintschev trauma department, jena university hospital, jena, germany isabel graul trauma department, jena university hospital, jena, germany arne wilharm trauma department, jena university hospital, jena, germany kajetan klos foot and ankle department, catholic medical center, mainz, germany gunther o. hofmann trauma department, jena university hospital, jena, germany; berufsgenossenschaftliche kliniken bergmannstrost halle, halle, germany

conclusions we recommend the additional 2d-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. the use of intraoperative 3d fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consum...

Journal: :Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 2013
Wakako Fukuda Chikashi Aoki Kazuyuki Daitoku Satoshi Taniguchi Ikuo Fukuda

Intra-and early post-operative aortic injury by pedicle screw is not a rare complication in orthopedic surgery, but aortic penetration by a screw head over a long time period is considered as an uncommon case. There are various surgical management options for thoracic aortic injury caused by malpositioned spinal instruments. We report a case of a patient who underwent minimally invasive graft r...

Journal: :Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery 2013
Cem Coşkun Avcı Deniz Gülabi Necdet Sağlam Tuhan Kurtulmuş Gürsel Saka

OBJECTIVES This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. PATIENTS AND METHODS Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesi...

Journal: :Journal of orthopaedic trauma 2011
Matthew J Bengard Michael J Gardner

Unstable and displaced proximal humerus fractures remain a treatment challenge. The use of locked plates has improved construct stability, but complication rates remain high. Biomechanical studies have emphasized the importance of anchoring screws in the subchondral bone of the humeral head to improve implant stability. However, the spherical shape of the proximal humerus and the limited tactil...

Journal: :Chinese medical journal 2015
Zhan-Le Zheng Xian Yu Wei Chen Yue-Ju Liu Kun-Lun Yu Tao Wu Ying-Ze Zhang

BACKGROUND Postoperative knee soft tissue irritation is a common complication after retrograde nail fixation of femoral fractures. Distal locking screw prominence is one of the causes for soft tissue irritation. This study aimed to determine whether the use of the femoral condyles tangential views improve the diagnostic accuracy compared with anteroposterior (A-P) view in detecting distal locki...

2014
Wei Tian Xiaoguang Han Bo Liu Yajun Liu Ying Hu Xiao Han Yunfeng Xu Mingxing Fan Haiyang Jin

OBJECTIVE To introduce a robot-assisted surgical system for spinal posterior fixation that can automatically recognize the drilling state and stop potential cortical penetration with force and image information and to further evaluate the accuracy and safety of the robot for sheep vertebra pedicle screw placement. METHODS The Robotic Spinal Surgery System (RSSS) was composed of an optical tra...

Journal: :Journal of Vascular Surgery 2013

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید