نتایج جستجو برای: rotational failure

تعداد نتایج: 402049  

Journal: :تحقیقات مهندسی کشاورزی 0
امیر صمدی دانشجوی دکتری پردیس کشاورزی و منابع طبیعی دانشگاه تهران ابراهیم امیری تکلدانی استادیار پردیس کشاورزی و منابع طبیعی دانشگاه تهران حسن رحیمی استاد پردیس کشاورزی و منابع طبیعی دانشگاه تهران

riverbank erosion, land loss and associated sedimentation are river engineering and water resources management problems of global significance. the ability to predict riverbank stability on eroding rivers is the prerequisite of developing a channel width adjustment model and is essential for estimating riverbank erosion and associated sedimentation. in this research, a detailed model for stabil...

Journal: :نشریه مهندسی عمران و نقشه برداری 0
فرج الله عسکری پژوهشگاه زلزله اورنگ فرزانه دانشگاه تهران مسعود فاضلی نیا دانشگاه تهران

this paper deals with three-dimensional evaluation of the slopes on the basis of limit analysis. an upper-bound technique of limit analysis is used in this paper to determine either the bearing capacity of a shallow foundation near a slope or the safety factor of the slope. the theorems of limit analysis (upper and lower bound) provide a powerful tool for solving problems in which limit loads n...

The significance of the seismic rotational components have been overlooked in the seismic evaluation of structural behavior. As researchers have measured seismic components more accurately using sensitive rotational velocity sensor, it was observed that the magnitude of rotational components is considerable and could not be neglected. Hence, some parts of seismic damage or failure of structures...

Journal: :Journal of orthopaedic trauma 2010
Travis C Burns Daniel J Stinner Daniel R Possley Andrew W Mack Tobin T Eckel Benjamin K Potter Joseph C Wenke Joseph R Hsu

OBJECTIVES Does the large zone of injury in high-energy, combat-related open tibia fractures limit the effectiveness of rotational flap coverage? DESIGN Retrospective consecutive series. SETTING This study was conducted at Brooke Army Medical Center, Walter Reed Army Medical Center, and National Naval Medical Center between March 2003 and September 2007. PATIENTS/PARTICIPANTS We identifie...

A. Ranjbaran, K. Mirzavand M. M. Goli Bidgoli M. Porhonar Y. Shajari Z. S. Seyedraoufi,

Application of thermoplastic materials has increased dramatically in recent decades due to its recyclability, low density, resistance to chemical changes. The friction stir welding process is one of the new methods of solid state welding, which has recently undergone a significant improvement. In this research, using a new tool Made of plain carbon steel st37 in friction stir welding and low co...

2012
Wojciech Zimoch Georg Gaul Marcin Wojtczak Piotr Kubler Krzysztof Reczuch

Highly calcified lesions in coronary arteries are a frequent cause of percutaneous coronary intervention failure. In such cases rotational atherectomy seems to be an efficient alternative that allows facilitation of the calcified atherosclerotic plaque and ensures successful treatment. We present a case of rotational atherectomy of the right coronary artery complicated with stent dislodgment an...

2007
Anthony A. Maciejewski Rodney G. Roberts

Kinematically redundant manipulators have been proposed for use in remote or hazardous environments due to their potential for tolerance to joint failures. This article deenes a local measure of failure tolerance based on the worst-case dexterity following a locked joint failure. Optimal values of this measure are identiied and related to the required structure of a Jacobian matrix. It is shown...

2013
Diego García-Germán Pablo Menéndez Samuel González Pablo de la Cuadra Ricardo Rodríguez-Arozena

We present the case of an extra-articular lateral tenodesis for an anterior cruciate ligament (ACL) deficient knee. A 46-year-old male patient sustained an ACL graft rupture after a motorcycle accident. He complained of rotational instability and giving-way episodes. His previous graft was fixed by an intra-articular femoral staple that was not possible to remove at the time of the ACL revision...

2016
Jochen Erhart Ewald Unger Philip Schefzig Peter Varga Inga Trulson Anna Gormasz Alexander Trulson Martin Reschl Michael Hagmann Vilmos Vecsei Winfried Mayr

BACKGROUND The current standard of care for operative repair of scaphoid fractures involves reduction and internal fixation with a single headless compression screw. However, a compression screw in isolation does not necessarily control rotational stability at a fracture or nonunion site. The single screw provides rotational control through friction and bone interdigitation from compression at ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید