نتایج جستجو برای: reinforced concrete column steel beam rcs

تعداد نتایج: 360446  

Hasan Aghabarati K. Parhizkar

Hybrid moment frame come together with reinforced concrete columns with structural steel beams (RCS). This Composite system provides several key advantages over current steel or concrete moment resisting frame. Past studies have shown this system to be efficient in both design and building stage while able to keep sufficient strength and necessary ductility in seismic zone.Although past researc...

H. Fazli,

Composite RCS building frames integrate reinforced concrete columns with structural steel beams to provide an efficient solution for the design and construction of earthquake-resisting structures. In this paper, an optimization framework is developed for performance-based seismic design of planar RCS moment resisting frames. The objective functions are defined as minimizing the construction cos...

Journal: :international journal of civil engineering 0
k. wang college of civil science and engineering, yangzhou univercity s.f. yuan college of civil science and engineering, yangzhou univercity d.f. cao phd professor, college of civil science and engineering, yangzhou univercity w.z. zheng phd professor, school of civil engineering, harbin institute of technology

this paper describes experimental and numerical investigations on two specimens of frames composed of steel reinforced concrete beam and angle-steel concrete column under horizontal low cyclic loading. based on the test results, the relationship curves of the horizontal load-displacement and the failure modes are acquired. meanwhile the hysteretic behaviors, skeleton curves, stiffness degradati...

In the present study, a new method for retrofitting reinforced concrete beam is introduced in which steel-concrete composite jackets containing steel fiber is used. For this purpose, 75% of the peripheral surface of reinforced concrete beams was initially reinforced using steel plates and bolts, and steel fiber reinforced concrete was used between the steel plates and the peripheral surfaces of...

Journal: :journal of the structural engineering and geotechnics 0
ali molaei manzar faculty of mechanics, islamic azad university, takestan branch, takestan, iran hassan aghabarati department of civil and architectural engineering, islamic azad university, qazvin branch, iran

dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. these walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. in this research intermediate dual system of steel moment frame was chosen with int...

2017
Muhammad N. S Hadi

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...

Ali Molaei Manzar Hassan Aghabarati,

Dual systems of steel moment frame and reinforced concrete shear wall have combined the advantages of steel frames and reinforced concrete shear wall. These walls have increased the lateral stiffness of steel frames and have reduced seismic demands on steel frames thus providing opportunities to use such system. In this research intermediate dual system of steel moment frame was chosen with int...

2013

Reinforced concrete structures consists of two main components and the behavior of these structures influenced by gender and material properties, in order to investigate the behavior of concrete reinforced beam that most important flexural element in reinforced concrete structures, we chosen High Strength Concrete (HSC) for concrete and GFRP and steel bars for reinforcement. For compare the new...

2017
Muhammad N. S Hadi

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection represents a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised steel straps were used...

2016
Changyong Li Xinxin Ding Shunbo Zhao Xiaoyan Zhang Xiaoke Li

Abstract: A new reinforced SFRFLC (abbr. steel fiber reinforced full-lightweight concrete) superposed beam was proposed to sufficiently utilize the good peculiarities of ordinary concrete in compression and SFRFLC in tension, and reduce its self-weight. Experimental study was carried out on the flexural behaviors of reinforced SFRFLC superposed beams compared with reinforced concrete beams and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید