نتایج جستجو برای: ray spectrometer
تعداد نتایج: 321697 فیلتر نتایج به سال:
Visible afterglow counterparts have now been detected for two GRBs (970228 and 970508) but are absent, with Lopt/Lγ ratios at least two orders of magnitude lower, for other GRBs, e.g., 970828. The causes of this variation are unknown. Any correspondence which could be discovered between the γ-ray properties of a GRB and its Lopt/Lγ would be useful, both in determining the GRB mechanisms, and in...
We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV-9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation...
In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...
he X-Ray/Gamma-Ray Spectrometer on the Near Earth Asteroid Rendezvous (NEAR) spacecraft will remotely sense X-ray and gamma-ray emissions from the surface of near-Earth asteroid 433 Eros and look for characteristic “signatures” in those emissions to determine its elemental composition. During the planned 10 months of orbits about Eros beginning in early 1999, data returned from the instrument w...
A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the spectrometer exploits conversion of gamma-rays into electrons via Compton scattering in a low-Z material. The scattered electron population is then spectrally resolved ...
A low-cost Commercial-Off-The-Shelf (COTS) 4H-SiC 0.06 mm2 UV p-n photodiode was coupled to a low-noise charge-sensitive preamplifier and used as photon counting X-ray spectrometer. The photodiode/spectrometer was investigated at X-ray energies from 4.95 keV to 21.17 keV: a Mo cathode X-ray tube was used to fluoresce eight high-purity metal foils to produce characteristic X-ray emission lines w...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید