BACKGROUND AND PURPOSE Radiologic evaluation of CSF leaks is a diagnostic challenge that often involves multiple imaging studies with the associated expense and patient discomfort. We evaluated the use of screening noncontrast high-resolution CT in identifying the presence and site of CSF rhinorrhea and otorrhea and compared it with contrast-enhanced CT cisternography and radionuclide cisternog...
Radionuclide cisternography is generally considered to be a safe procedure without significant neurological complications. However, in this report we present a patient who developed conus medullaris syndrome following radionuclide cisternography. A 46-year-old woman underwent lumbar puncture followed by radionuclide cisternography with the diagnosis of hydrocephalus. After the cisternography, s...
The authors present the case of a 55-year-old man suffering from intractable spontaneous intracranial hypotension, in whom conservative treatment with 19 weeks of bed rest was not effective. In this period the patient twice underwent surgery for bilateral chronic subdural hematoma, a complication of spontaneous intracranial hypotension. Conventional radionuclide cisternography, magnetic resonan...
UNLABELLED Radionuclide cisternography is an indispensable examination to detect cerebrospinal fluid (CSF) leakage in patients suspected of having spontaneous intracranial hypotension (SIH). However, it sometimes fails to demonstrate the site of CSF leakage, and in such cases, early bladder visualization is utilized for the diagnosis of SIH as an indirect finding. The aim of this work is to imp...
In 1791 , Mondini described a membranous and bony dysplasia of the inner ear in a congenitally deaf child (1]. Classically, the Mondini deformity consists of a cochlea containing a normal basal turn and a total of 1.5 rather than 2.5 turns; the middle and apical turns are incorporated into a single sac. Because dysplasia of the labyrinth may be associated with dural dehiscence and a bony defect...
Received 7/21/2006; revised 8/11/2006; accepted 8/15/2006. For correspondence or reprints contact: Su-Mei Chen, M.D., Division of Nuclear Medicine, Taipei City Hospital, Renai Branch, 10 Section 4, Renai Road, Daan District, Taipei 106, Taiwan. Tel: (886)2-27093600 ext. 5117, Fax: (886)227037710, E-mail: [email protected] The purpose of this case report is to demonstrate the utility of SPECT c...