نتایج جستجو برای: radiofrequency catheter ablation
تعداد نتایج: 93011 فیلتر نتایج به سال:
conclusions we can conclude that treatment of af using a right-sided minithoracotomy approach and rf energy in patients undergoing cardiac surgery for various valve diseases is feasible, safe, and reproducible. objectives our aim is to evaluate the feasibility, safety, and immediate plus medium-term results of concomitant af ablation therapy in patients undergoing minimally invasive valve surge...
background: after radiofrequency catheter ablation of arrhythmias, patients have to bed rest for 4-6 h to prevent bleeding and hematoma. however, such a rest may cause back pain in the patients. the aim of this study was to determine the effects of continuous change in body position during and after the radiofrequency ablation on the back pain. materials and methods: in a quasi‑experimental des...
AIMS Although arrhythmia surgery and radiofrequency catheter ablation to cure atrioventricular nodal reentrant tachycardia differ in technical concept, the late results of both methods, in terms of elimination of the arrhythmogenic substrate and procedure-related new and different arrhythmias, have never been compared. This constituted the purpose of this prospective follow-up study. METHODS ...
BACKGROUND Catheter radiofrequency ablation of ventricular arrhythmias (VAs) arising from the left ventricle's papillary muscles has been associated with inconsistent results. The use of cryoenergy versus radiofrequency has not been compared yet. This study compares outcomes and complications of catheter ablation of VA from the papillary muscles of the left ventricle with either cryoenergy or r...
An increase in cardiac radiofrequency catheter ablation for treating refractory atrial fibrillation has resulted in an increased prevalence of complications. Among numerous complications of radiofrequency catheter ablation, atrio-esophageal fistula, although rare, is known to have fatal results. We report a case of successful management of an atrio-esophageal fistula as a complication of cardia...
BACKGROUND Complications concerning the coronary arteries that are directly related to radiofrequency catheter ablation procedures have not been reported in children. Coronary artery lesions, however, have been demonstrated after the endocardial application of radiofrequency current in young animals. METHODS AND RESULTS Two boys with Ebstein's anomaly of the tricuspid valve developed clinical...
PURPOSE OF REVIEW The purpose of the review is to provide an update on the safety and efficacy of catheter cryoablation. RECENT FINDINGS Catheter cryoablation is a safe and clinically effective method for ablation of atrioventricular nodal reentrant supraventricular tachycardia. Although the acute procedural success rate of catheter cryoablation for this arrhythmia may be slightly lower than ...
BACKGROUND Epicardial radiofrequency catheter ablation of ventricular tachycardia remains challenging because of the presence of deep myocardial scar and adjacent cardiac structures, such as the coronary arteries, phrenic nerve, and epicardial fat that limit delivery of radiofrequency energy. High-intensity ultrasound (HIU) is an acoustic energy source able to deliver deep lesions through fat, ...
Sixteen patients with type I atrial flutter underwent an attempt at radiofrequency catheter ablation (8 women, 8 men, mean age 53 +/- 11 years). The primary criterion used to identify sites for radiofrequency energy delivery was the identification of a fractionated electrogram. Radiofrequency energy was delivered for 20 to 30 seconds. Radiofrequency catheter ablation was acutely successful in 1...
Ablation of the atrioventricular junction with radiofrequency energy using a new electrode catheter.
Percutaneous catheter ablation using radiofrequency energy can be used to interrupt atrioventricular (AV) conduction in patients with supraventricular tachycardia refractory to drugs. Results of radiofrequency ablation of the AV junction using a custom-designed catheter with a large, 3-mm-long distal electrode, 2-mm interelectrode spacing, and a shaft with increased torsional rigidity were comp...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید