نتایج جستجو برای: r600a

تعداد نتایج: 89  

2015
Deepak Paliwal

An experimental performance study on VCR system with 100g R600a/R290 refrigerant mixture and 100g R600a (pure isobutene) as drop in replacement of R134a was conducted . continuation running tests were performed under different length of capillary for R600a/R290 & R600a. The result showed that the hydrocarbon mixture (R600a/R290) had highest COP at L=10 feet length capillary by17.35% -23.5% for ...

1998
I. L. Maclaine-cross E. Leonardi

Measurements on R600a refrigerators have shown electricity savings over R134a and R12 up to 20%. We propose new parameters which are functions of well known refrigerant properties. These parameters show that R600a has half the leakage, pressure loss and condenser pressure and double the heat transfer coefficient of R12 and R134a explaining the measurements. Use of R600a in small heat pumps and ...

2013
Xianbiao Bu Lingbao Wang Huashan Li

Results: The calculated results show that because of high system pressure for R290 and R134a, R600a is the more suitable working fluid for ORC in terms of expander size parameter, system efficiency and system pressure. In addition, R600a is also the most appropriate working fluid for VCC in terms of pressure ratio and coefficient of performance. R600 and R600a are more suitable working fluids f...

Journal: :E3S web of conferences 2023

This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodified R-22 AC was charged with R152a/R290/R600/R600a. During the experiment, parameters such coefficient of...

2006
PIOTR A. DOMANSKI DAVID YASHAR

This paper presents an analytical evaluation of isobutane (R600a), propane (R290), R134a, R22, R410A, and R32 in a vapor compression system used for comfort cooling applications. The evaluation method was based on a system simulation model that was complimented with an evolutionary computation module for the optimization of refrigerant circuitries in the evaporator and condenser. The evaluation...

Journal: :Thermal Science 2021

In this study, the thermal performance of an internal heat exchanger-organic flash cycle system driven by geothermal water was investigated. The R600a/R601a mixtures were selected as working fluid. effects mole fraction on absorption capacity heater, temperature rise cold fluid in exchanger, net power output, efficiency, and electricity generation costs analyzed. outputs, costs, efficiency simp...

2014
R S Mishra

The methods for improving second law efficiency have been considered in this paper by using liquid vapour heat exchanger is investigated in this paper. Detailed energy and exergy analysis of multi-evaporators at different temperatures with single compressor and single expansion valve using liquid vapour heat exchanger vapour compression refrigeration systems have been done in terms of performan...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه اصفهان - دانشکده فنی و مهندسی 1390

چکیده مبرد r134a که در دو دهه گذشته معمول ترین مبرد در یخچال های خانگی بوده است، به دلیل اثرات گلخانه ای شدید آن طبق پروتکل کیوتو باید تولید و مصرف آن کاهش یابد لذا در چند سال گذشته تحقیقات فراوانی در مورد جایگزینی این مبرد با هیدروکربن های پروپان، نرمال بوتان و ایزوبوتان به عمل آمده است. در این تحقیق عملکرد دو نوع مبرد هیدروکربنی با میزان شارژهای متفاوت در یک یخچال فریزر خانگی بررسی شد تا معل...

افزایش قیمت سوخت و محدودیت انتشار آلاینده دی‌اکسید کربن سبب ایجاد روش‌های مختلفی برای افزایش بازده گرمایی موتورهای احتراق داخلی شده است. یکی از این روش­ها تبدیل انرژی گرمایی تلف‌شده موتور به انرژی مکانیکی یا الکتریکی است. در این پژوهش به بررسی و بکارگیری گرمای اتلافی از گازهای خروجی موتور احتراق داخلی MTU-16V، در یک چرخه رانکین آلی برحسب راندمان قوانین اول و دوم ترمودینامیک پرداخته ‌شده است. با...

2014
Bo Shen Pradeep Bansal Bo SHEN Pradeep BANSAL

This paper presents technical assessment of environmentally friendly refrigerants as alternatives to R410A for window air conditioners. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R41...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید