نتایج جستجو برای: pulsed electron beam

تعداد نتایج: 432420  

Journal: :iranian journal of radiation research 0
k. rajesha nairy depatment of studies in physics, mangalore university, mangalagangotri-574 199, india n.n. bhat radiological protection and advisory division, bhabha atomic research center, mumbai-400 085, india p. joseph depatment of studies in physics, mangalore university, mangalagangotri-574 199, india g. sanjeev depatment of studies in physics, mangalore university, mangalagangotri-574 199, india n. yerol depatment of studies in physics, mangalore university, mangalagangotri-574 199, india

background: exposure to ionizing radiation is known to induce oxidative stress followed by damage to critical biomolecules like lipids, proteins and dna through radiolysis of cellular water. since radiation has been widely used as an important tool in therapy of cancer, the detailed investigation regarding the dna damage and repair kinetics would help to predict the radiation sensitivity of cel...

2013
M. S. Cohen R. C. Johnston M. S. COHEN R. C. JOHNSTON

A pulsed, 20 kv electron beam is focussed upon a vapor-deposited thermocouple, and the resulting temperature vs. time response is studied. The experimental data show much scatter, but are consistent with the theoretical prediction that the characteristic thermal response time T is proportional to d , where d is the beam diameter at the thermocouple. From these data, for the soft-glass substrate...

G. Sanjeev, K. Rajesha Nairy, N. Yerol, N.N. Bhat, P. Joseph,

Background: Exposure to ionizing radiation is known to induce oxidative stress followed by damage to critical biomolecules like lipids, proteins and DNA through radiolysis of cellular water. Since radiation has been widely used as an important tool in therapy of cancer, the detailed investigation regarding the DNA damage and repair kinetics would help to predict the radiation sensitivity of cel...

1998
K. Batchelor J. P. Farrell I. Ben-Zvi T. Srinivasan-Rao J. Smedley V. Yakimenko

This paper describes a pulsed electron gun that can be used as an FEL, as an injector for electron linear accelerators or for rf power generation. It comprises a 1 to 5 MeV, 1 to 2 ns pulsed power supply feeding a single diode, photoexcited acceleration gap. Beam quality of a ~ 1nC charge in ~ 1 GV/m field was studied. Computations of the beam parameters as a function of electrode configuration...

Journal: :Journal of geomagnetism and geoelectricity 1988

Journal: :Journal of the Japan Society of Precision Engineering 1985

2001
S. Korenev

The investigation of current transformers for measurements of beam current for relativistic electrons in air is presented in this report. The industrial CW electron accelerator “Rhodotron” ( E = 5 MeV, I = 1-16 mA) was used for experiments. The effect of scanning electron beam allows pulsed current transformers to be used for measurements of beam current. The comparison of beam current measurem...

1999
G. F. Popov A. I. Kalinichenko

This paper describes a method and a control system of a scanning electron and a bremsstrahlung pulsed beam for industrial linac. The system uses ultrasonic emission generated by the beam in thin rods and plates, as a source of primary information about the current characteristics of each electron/bremsstrahlung pulse. The results of the uniform radiation field forming are discussed.

Journal: :Journal of physics 2021

Abstract Nanopowders doped with silver were produced by the methode pulsed electron beam evaporation.

2005
A. Laakso

We show that the timing properties of a pulsed low-energy positron lifetime beam can be conveniently tested by an electron beam. We apply this method to study time resolution of the beam and electron scattering in a flat and a ’sawtooth’ shaped choppers. The results show that (i) time resolution of 160 ps is obtained, (ii) the scattering of the electrons and the secondary electron yield of the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید