نتایج جستجو برای: pulse function
تعداد نتایج: 1292234 فیلتر نتایج به سال:
in this paper, we introduce hybrid of block-pulse functions and bernstein polynomials and derive operational matrices of integration, dual, differentiation, product and delay of these hybrid functions by a general procedure that can be used for other polynomials or orthogonal functions. then, we utilize them to solvedelay differential equations and time-delay system. the method is based upon ex...
in this work, we present a computational method for solving second kindnonlinear fredholm volterra integral equations which is based on the use ofhaar wavelets. these functions together with the collocation method are thenutilized to reduce the fredholm volterra integral equations to the solution ofalgebraic equations. finally, we also give some numerical examples that showsvalidity and applica...
polyphase is a common class of pulse compression waveforms in the radar systems. oppermann code is one of the used codes with polyphone pattern. after compression, this code has little tolerant against doppler shift in addition to its high side lobe level. this indicates that the use of oppermann code is an unsuitable scheme to radars applications. this paper shows that the use of amplitude wei...
heat stress effects on physical and mental health of workers and decreases human function. asphalt workers are both exposed to the heat of their working process and to the sun heat. this study aimed at evaluating thermal stress and its following function fall and the effect of asphalt work on the degree of heat stress and asphalt workers’ physiological parameters. the present study was done at ...
Backgraound: It is recommended to use BIS (BISpectral) to determine anesthesia levels. Currently, due to low capacity in Iran, anesthesiologists use cardiac indices, such as pulse rates and blood pressure to detect anesthesia levels. This study was designed to assess association of cardiac parameters with anesthesia levels measured by brain function. Methods: In this descriptive study, 14 pati...
we have simulated the carrier concentration and temporal response characteristics of a back-gated metal- semiconductor-metal (bg-msm) photodetector in one dimension as a function of optical pulse position on the active region in an equilibrium condition (without bias voltage to the photodetector). we have adopted a nonlinear ambipolar transport model to simulate the behavior of photo-generated ...
pulse echo b - scan imaging systems have been used for years in medical diagnosis. the theroy of such systems have been investigated by several researchers. in this paper, we introduce a new model for b - scan imaging system based on gaussian type transducer. an imaging system is normally identified by its point response function. this function describes the image of a single physical point obj...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید