نتایج جستجو برای: power transformer protection

تعداد نتایج: 666345  

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی خواجه نصیرالدین طوسی - دانشکده مهندسی برق و کامپیوتر 1391

power transformers are important equipments in power systems. thus there is a large number of researches devoted of power transformers. however, there is still a demand for future investigations, especially in the field of diagnosis of transformer failures. in order to fulfill the demand, the first part reports a study case in which four main types of failures on the active part are investigate...

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...

Journal: :مهندسی قدرت ایران 0
reza shariatinasab university of birjand, iran z ejtemaee university of birjand, iran j gholinezhad university of birjand, iran

power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. the resonant overvoltages may destroy the insulation between turns and cause to insul...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تهران 1387

چکیده ندارد.

2015
Arpit Rana Jeet Shah Anuradha Deshpande

Power transformers are key components for electrical energy transfer in a Power system. In order to protect the transformers from these faults different protective methods are adopted. Some of them are differential protection, over excitation Protection, etc. In this Paper Over Voltage protection is established for the protection of the transformer. Microcontroller is used for the Power Transfo...

2007
Zoran Gajić

This thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection for such applications is considered impossible in ...

A. A. Abdoos A. Ebadi S. M. Hosseini,

The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید