background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...
Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...
The exciton scattering (ES) approach attributes excited electronic states in quasi-1D branched polymer molecules to standing waves of quantum quasiparticles (excitons) scattered at the molecular vertices. We extract their dispersion and frequency-dependent scattering matrices at termini, ortho, and meta joints for pi-conjugated phenylacetylene-based molecules from atomistic time-dependent densi...
background: monte carlo method (mc) has played an important role in design and optimization of medical linacs head and beam modeling. the purpose of this study was to compare photon beam features of two commercial linacs, varian 21ex and elekta sl-25 using mcnp4c mc code. materials and methods: the 6mv photon beams of varian 21ex and elekta sl-25 linacs were simulated based on manufacturers pro...
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
Recent studies suggest that relative biological damage (RBD) may change from in to out of field regions for 6 MV photon beams. In this study RBD was calculated in and out of field of 30x30 cm2 and 40x40 cm2 6 MV clinical photon beams including low energy slowing down electrons in track length estimated method. Varian 2100C/D linear accelerator was simulated using MCNPX code. Electron and photon...
Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...
Purpose: To investigate the energy dependence/spectral sensitivity of silicon diodes designed for small-field dosimetry and obtain response factors (RFs) for arbitrary photon spectra using Monte Carlo (MC) simulations. Methods: The EGSnrc user-code DOSRZnrc was used to calculate the dose deposition in water and in the active volume of a stereotactic diode f...
The luminosity distribution in the effective γγ mass at photon collider has usually two peaks which are well separated: High energy peak with mean energy spread about 5− 7% and wide low energy peak. The low energy peak depends strongly on details of design and it is unsuitable for the study of New Physics phenomena. We find simple approximate form of spectra of collided photons for γγ and eγ co...