Journal: :iranian journal of medical physics 0
m. ashkanmehr m.sc. in nuclear engineering dept., islamic azad university, tehran, iran. n. riyahi alam associate professor, physics and biomedical engineering, tehran university of medical sciences, tehran, iran. research center for science & technology in medicine, imam khomeini hospital, tehran. iran. m.a. oghabian associate professor, physics and biomedical engineering, tehran university of medical sciences, tehran, iran. research center for science & technology in medicine, imam khomeini hospital, tehran. iran. a. ghasemzadeh m. sc. in research center for science & technology in medicine, imam khomeini hospital, tehran. iran. m. bakhtiary m. sc. in research center for science & technology in medicine, imam khomeini hospital, tehran. iran. h. ghanaati associate professor, radiology dept., medical imaging center, imam khomeini hospital, tehran university of medical sciences , tehran, iran.

introduction:  image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (mri) for use in 3dmri, velocity mri, fmri and radiotherapy treatment planning (rttp). it is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  geometric  distortion  of  mr  tomograms.  in  this  study,  the...

2015
Susanne Ziegler Bjoern W. Jakoby Harald Braun Daniel H. Paulus Harald H. Quick

BACKGROUND In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements...

Journal: :iranian journal of nuclear medicine 2009
d shahbazi-gahrouei s nikzad p shokrani z shahi sh monadi

introduction: in patients with thyroid carcinoma, radiation absorbed doses of the thyroid and surrounding tissues is important to weigh risk and benefit considerations. in nuclear medicine, the accuracy of absorbed dose of internally distributed radionuclides is estimated by different methods such as mird and direct method using tld. the aim of this study is using tld and a phantom to determine...

2013
Vilma Mannila Outi Sipilä

BACKGROUND Recommended phantom-based quality assurance measurements in B-mode ultrasound (US) may be tedious. For the purpose of cost-effective US quality assurance it is important to evaluate measurements that effectively reflect the quality of US scanner. PURPOSE To find out which recommended phantom-based quality assurance measurements are effective in detecting dead or weak transducer ele...

2010
Brian J Holland Beth F Printz Wyman W Lai

BACKGROUND One potential source of error in phase contrast (PC) congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has been shown to result in more accurate measurements of blood flow in adults with structurally normal hearts. We report the effect of phantom correction on PC flow measurements at...

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

A. Ghasemzadeh H. Ghanaati H. Hashemi M. Ashkanmehr M. Bakhtiary M. Pakravan M.A. Oghabian N. Riyahi Alam N. Shakeri

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

Journal: :Journal of applied physiology 2000
E Diessel T Fuerst C F Njeh F Tylavsky J Cauley M Dockrell H K Genant

This study evaluated a new body composition phantom and its use for quality control and cross-calibration of dual-energy X-ray absorptiometry (DXA) instruments for measurements of body composition. We imaged the variable composition phantom (Lunar, Madison, WI) on eight different DXA devices. Deviations of up to 7% fat were observed when we compared the percent fat values measured by the differ...

I.A. Kim, J.B. Chung, J.S. Kim, J.W. Lee, K.Y. Eom, M.J. Kim, S.W. Kang, T.S. Suh, Y.L. Kim,

Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a           6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...

2012
Masahiro Nakano Robin F. Hill May Whitaker Jung‐Ha Kim Zdenka Kuncic

The present study quantified surface doses on several rectangular phantom setups and on curved surface phantoms for a 6 MV photon field using the Attix parallel-plate chamber and Gafchromic EBT2 film. For the rectangular phantom setups, the surface doses on a homogenous water equivalent phantom and a water equivalent phantom with 60 mm thick lung equivalent material were measured. The measureme...