نتایج جستجو برای: percent depth dose

تعداد نتایج: 559005  

Journal: :iranian journal of medical physics 0
m. j. tahmasebi birgani associate professor, medical physics dept., ahwaz university of medical sciences, ahwaz, iran. m. ghorbani ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran.

introduction:  on  the  basis  of  percent  depth  dose  (pdd)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. the aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of cobalt-60 beam.   materials and methods: in the present study, based on ...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri shahid sadoughi university of medical sciences, yazd, iran m. kiani tabriz university of medical sciences, medical physics, tabriz, iran a.r. farajollahi tabriz university of medical sciences, medical physics, tabriz, iran

background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...

M. Ghorbani M. J. Tahmasebi Birgani

Introduction:  On  the  basis  of  percent  depth  dose  (PDD)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of Cobalt-60 beam.   Materials and Methods: In the present study, based on ...

2007
Michael J. Price Kenneth R. Hogstrom John A. Antolak R. Allen White Charles D. Bloch Robert A Boyd

In the present work, we investigated the accuracy of the electron pencil-beam redefinition algorithm (PBRA) in calculating central-axis percent depth dose in water for rectangular fields. The PBRA energy correction factor C(E) was determined so that PBRA-calculated percent depth dose best matched the percent depth dose measured in water. The hypothesis tested was that a method can be implemente...

Journal: :iranian journal of radiation research 0
m.t. bahreyni toossi department of medical physics, faculty of medicine, mashhad university of medical sciences, mashhad, iran a.r. khoshbin khoshnazar

background: radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. the presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. materials and methods : small circular fields w...

A.R. Khoshbin Khoshnazar, M.T. Bahreyni Toossi,

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...