Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...
The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...
This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for atte...
Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...
background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...
Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 ma...
introduction: the pagat polymer gel dosimeter melts at 30 ˚c and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. to increase the stability of the pagat gel, different amounts of agarose were added to the pagat gel composition and the pagata gel was manufactured. material and methods: the pagata gel vials were irradiated using a co-60 ma...
Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...
background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...