2011
B. Azadbakht

Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...

2012
B. Azadbakht

The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...

B. Azadbakht, k. Hadad, M.H. Zahmatkesh, S. Bagheri,

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

Journal: :iranian journal of radiation research 0
b. azadbakht department of nuclear engineering, shiraz university, shiraz, iran m.h. zahmatkesh novin medical research institute, tehran, iran k. hadad department of nuclear engineering, shiraz university, shiraz, iran s. bagheri novin medical research institute, tehran, iran

background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...

*, Mohammad Hassan Zahmatkesh Bakhtiar Azadbakht, Kamal Haddad Saeid Bagheri

Introduction: The PAGAT polymer gel dosimeter melts at 30 ˚C and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. To increase the stability of the PAGAT gel, different amounts of agarose were added to the PAGAT gel composition and the PAGATA gel was manufactured. Material and Methods: The PAGATA gel vials were irradiated using a Co-60 ma...

2014
Parvin Mohammadyari Mehdi Zehtabian Sedigheh Sina Ali Reza Tavasoli Reza Faghihi

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft-versus-host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 ...

Journal: :iranian journal of medical physics 0
bakhtiar azadbakht instructor, medical radiation engineering dept, faculty of engineering, borujerd islamic azad university, borujerd, iran. *, mohammad hassan zahmatkesh associate professor, shahid beheshti university, evin, tehran, iran kamal haddad associate professor, nuclear engineering dept, faculty of engineering, shiraz university, shiraz, iran. saeid bagheri m.sc. in medical physics, shahid beheshti university, tehran, iran

introduction: the pagat polymer gel dosimeter melts at 30 ˚c and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. to increase the stability of the pagat gel, different amounts of agarose were added to the pagat gel composition and the pagata gel was manufactured. material and methods: the pagata gel vials were irradiated using a co-60 ma...

Journal: :Journal of Physics: Conference Series 2015

2014
A Asena T Kairn S B Crowe S T Smith

This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for atte...

Journal: :Journal of Physics: Conference Series 2013