نتایج جستجو برای: omron

تعداد نتایج: 347  

Journal: :Vascular Health and Risk Management 2007
Jirar Topouchian Davide Agnoletti Jacques Blacher Ahmed Youssef Isabel Ibanez Jose Khabouth Salwa Khawaja Layale Beaino Roland Asmar

BACKGROUND Four oscillometric devices for self-measurement of blood pressure (SBPM) were evaluated according to the European Society of Hypertension (ESH) international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP) at the brachial level, while the Omron R2 measures BP at the wrist level. METHODS The international pro...

Journal: :Journal of rehabilitation research and development 2015
Valery A Danilack Osarenoma Okunbor Caroline R Richardson Merilee Teylan Marilyn L Moy

Objective assessment of physical activity (PA) in chronic obstructive pulmonary disease (COPD) is important. We examined the performance of the Omron HJ-720ITC pedometer. A sample of 176 persons with stable COPD wore the Omron and the StepWatch Activity Monitor (SAM) in the clinic and the community. A 4 s step filter in the Omron screens out erroneous intermittent steps; it captures continuous ...

Journal: :Journal of rehabilitation research and development 2010
Marilyn L Moy Adrienne W Janney Huong Q Nguyen Kirby R Matthess Miriam Cohen Eric Garshick Caroline R Richardson

We evaluated an Internet-mediated, pedometer-based program to promote walking in chronic obstructive pulmonary disease (COPD). First, we assessed the accuracy of the Omron HJ-720ITC pedometer (OMRON Healthcare, Inc; Bannockburn, Illinois) in 51 persons with COPD. The Bland-Altman plot showed a median difference of 3 steps (5th and 95th quintiles, -8.0 and 145.0, respectively). We calculated per...

Journal: :Blood pressure monitoring 2009
Martin G Myers Miguel Valdivieso Alexander Kiss Sheldon W Tobe

OBJECTIVE To compare readings obtained using two automated blood pressure (BP) recording devices, BpTRU and Omron 907, in a clinical setting. METHODS Two series of 50 patients attending a hypertension unit for 24-h ambulatory BP monitoring had BP recorded either every 1 or every 2 min using BpTRU and Omron 907 devices with the order of the measurements being randomized. RESULTS No significa...

Journal: :Arquivos brasileiros de cardiologia 2011
Lina M Vera-Cala Myriam Orostegui Laura I Valencia-Angel Nahyr López Leonelo E Bautista

BACKGROUND Accurate measurement of blood pressure is of utmost importance in hypertension research. In the context of epidemiologic and clinical studies, oscillometric devices offer important advantages to overcome some of the limitations of the auscultatory method. Even though their accuracy has been evaluated in multiple studies in the clinical setting, there is little evidence of their perfo...

Journal: :Journal of physical activity & health 2011
Jeremy A Steeves Brian M Tyo Christopher P Connolly Douglas A Gregory Nyle A Stark David R Bassett

BACKGROUND This study compared the validity of a new Omron HJ-303 piezoelectric pedometer and 2 other pedometers (Sportline Traq and Yamax SW200). METHODS To examine the effect of speed, 60 subjects walked on a treadmill at 2, 3, and 4 mph. Twenty subjects also ran at 6, 7, and 8 mph. To test lifestyle activities, 60 subjects performed front-back-side-side stepping, elliptical machine and sta...

2017
Alaa Azaki Reem Diab Aya Harb Roland Asmar Mirna N Chahine

OBJECTIVE Two oscillometric devices, the Microlife WatchBP O3® and the Omron RS6®, designed for self-blood pressure measurement were evaluated according to the European Society of Hypertension (ESH)-International Protocol (IP) Revision 2010 in the obese population. METHODS The Microlife WatchBP O3 measures blood pressure (BP) at the brachial level and the Omron RS6 measures BP at the wrist le...

Journal: :Blood pressure monitoring 2003
Mohamed A El Assaad Jirar A Topouchian Roland G Asmar

BACKGROUND Two devices for self-measurement of blood pressure at the brachial artery-the Omron M5-I and the Omron 705IT-were evaluated according to the international protocol of the European Society of Hypertension. DESIGN The international validation protocol is divided into two phases: the first phase is performed on 15 selected subjects and if the device passes this phase, 18 supplementary...

Journal: :American journal of hypertension 2011
Feng-Hua Ding Wang-Xiang Fan Rui-Yan Zhang Qi Zhang Yan Li Ji-Guang Wang

BACKGROUND To investigate the accuracy of the SphygmoCor and Omron HEM9000-AI devices in the estimation of central blood pressure (BP) in comparison with the simultaneous invasive catheter measurement. METHODS The radial arterial pulse was sequentially recorded by the use of the Omron and SphygmoCor devices in 33 patients, with the calibration of the brachial oscillometric BP, to derive centr...

2014
Jirar Topouchian Davide Agnoletti Jacques Blacher¹ Ahmed Youssef Mirna N Chahine Isabel Ibanez Nathalie Assemani Roland Asmar

BACKGROUND Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. METHODS The four devices measure brachial blood pressure (BP) using the oscillomet...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید