نتایج جستجو برای: microbubble

تعداد نتایج: 1643  

Journal: :Physical review. E 2017
Matthieu Guédra Sarah Cleve Cyril Mauger Philippe Blanc-Benon Claude Inserra

Time-resolved dynamics of nonspherical oscillations of micrometer-sized bubbles are captured and analyzed using high-speed imaging. The axisymmetry of the bubble shape is ensured with certainty for the first time from the recordings of two synchronous high-speed cameras located at 90^{∘}. The temporal dynamics of finite-amplitude nonspherical oscillations are then analyzed for various acoustic ...

Journal: :Acta biomaterialia 2012
Nikolitsa Nomikou Poonam Tiwari Tanvi Trehan Kriti Gulati Anthony P McHale

Ultrasound-mediated gene transfer is emerging as a practical means of facilitating targeted gene expression and is significantly enhanced in the presence of exogenously added microbubbles. This study explores the influence of microbubble surface modifications on their interaction with plasmid DNA and target cells, and the functional consequences of those interactions in terms of ultrasound-medi...

Journal: :Internal medicine 2013
Shiho Tokunaga Masahiko Koda Jun Kato Kenichi Miyoshi Manabu Kishina Yuki Fujise Tomomitsu Matono Yoshikazu Murawaki

OBJECTIVE It is important to detect post-liver biopsy hemorrhage early and confirm hemostasis in the clinical setting. Contrast-enhanced ultrasound (CEUS) is a sensitive and highly specific tool for detecting active bleeding. The aim of this study was to investigate the rate of detection of track microbubble flow signals on CEUS with perflubutane following liver biopsy and to assess the disappe...

Journal: :Journal of hazardous materials 2009
Joo Young Park Yong Ju Choi Seheum Moon Do Yun Shin Kyoungphile Nam

The applicability of microbubble suspension made of saponin as a biodegradation-enhancing carrier where oxygen and pollutant-degraders are limited was studied. The saponin-microbubble suspension was used to deliver phenanthrene-degrading bacteria, inorganic nutrients, and oxygen. Bench-scale study was carried out to determine the physical properties of the microbubble suspension and to verify w...

2017
Klazina Kooiman Tom van Rooij Bin Qin Frits Mastik Hendrik J Vos Michel Versluis Alexander L Klibanov Nico de Jong Flordeliza S Villanueva Xucai Chen

Acoustic behavior of lipid-coated microbubbles has been widely studied, which has led to several numerical microbubble dynamics models that incorporate lipid coating behavior, such as buckling and rupture. In this study we investigated the relationship between microbubble acoustic and lipid coating behavior on a nanosecond scale by using fluorescently labeled lipids. It is hypothesized that a l...

Journal: :Physical review letters 2010
G N Sankin F Yuan P Zhong

The interaction of laser-generated tandem microbubble (maximum diameter of about 50  μm) with single (rat mammary carcinoma) cells is investigated in a 25-μm liquid layer. Antiphase and coupled oscillation of the tandem microbubble leads to the formation of alternating, directional microjets (with max microstreaming velocity of 10  m/s) and vortices (max vorticity of 350 000  s{-1}) in opposite...

Journal: :BioMed research international 2016
Joe Fiabane Paul Prentice Ketan Pancholi

Microfluidic approaches to microbubble production are generally disadvantaged by low yield and high susceptibility to (micro)channel blockages. This paper presents an alternative method of producing microbubbles of 2.6 μm mean diameter at concentrations in excess of 30 × 10(6) mL(-1). In this method, the nitrogen gas flowing inside the liquid jet is disintegrated into spray of microbubble when ...

Journal: :The Malaysian journal of pathology 1996
K B Cheong S K Cheong N Y Boo

This study aimed to determine the role of surfactant protein A (SP-A) in the formation of stable microbubble in tracheal aspirates. Our results showed that as the concentration of anti SP-A antibodies added to tracheal aspirate specimens increased, the number of stable microbubble formed in the specimen decreased. The correlation between stable microbubble counts and the SP-A levels in the trac...

2007
Li-Bing Chu Xin-Hui Xing An-Feng Yu Xu-Lin Sun Benjamin Jurcik Li-bing Chu

In this paper the microbubble technology was employed to increase the mass transfer rate of ozone as well as to enhance the ozone oxidation. Experiments were performed using the microbubbles generator and the bubble contactor, which is commonly used in ozonation system, for the purpose of comparison. The microbubble generator produced a milky and high intensity microbubble solution in which the...

Journal: :The journal of extra-corporeal technology 2013
Daniel P Herbst

Improvements in micropore arterial line filter designs used for extracorporeal circulation are still needed because microbubbles larger than the rated pore sizes are being detected beyond the filter outlet. Linked to principles governing the function of micropore filters, fluid pressures contained in extracorporeal circuits also influence the behavior of gas bubbles and the extent to which they...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید