نتایج جستجو برای: magat gel dosimeter
تعداد نتایج: 106939 فیلتر نتایج به سال:
background: an effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. materials and methods: the magat gel dosimeter formulations that used different compositions of methacrylic acid (maa) and gelatin were extensively investigated in the present study according to the r2–dose response and r2–dose sensitivity. the irradiation of magat gel was per...
Background: An effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. Materials and Methods: The MAGAT gel dosimeter formulations that used different compositions of Methacrylic acid (MAA) and gelatin were extensively investigated in the present study according to the R2–dose response and R2–dose sensitivity. The irradiation of M...
background: in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...
Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods: Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...
Proton pencil beam scanning is a dynamic delivery technique with excellent conformability to the tumor volume. The accuracy of spot size and positions will have significant effect on delivered dose distribution. We employed polymer gel dosimeters measure for Shanghai Advanced Therapy facility (SAPT). Polymer (MAGAT-f PAGAT) were utilized full width at half maximum (FWHM) various depths basis th...
This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in...
Background: Numerous unique characteristics of the nanosized gold, including high atomic number, low toxicity, and high biocompatibility make it one of the most appropriate nanostructures to boost radiotherapy efficacy. Many in-vivo and in-vitro investigations have indicated that gold nanoparticles (AuNPs) can significantly increase tumor injuries in low kilovoltage radiotherapy. While deep-lyi...
Background: In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...
The present work compared the relative absorbed dose of some dosimetric materials, for energies 250 kV and 6 MV, using PENELOPE MNCPX codes. composition each material GD-301, TLD-100, MAGIC, MAGAT were simulated disposed in a phantom filled with water following reference conditions recommended by TRS-398 protocol. Percentage depth was used as parameter comparison. Since obtained results both co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید