نتایج جستجو برای: lens

تعداد نتایج: 50659  

Journal: :مجله دانشکده پزشکی دانشگاه علوم پزشکی تهران 0
احمد جوادیان a javadian

in view of the rapid expansion of contact lens amongst the users, new dimensions have been added to the domain of ophthalmology: giant papillay conjunctivitis, a disease caused by different kinds of contact lens, appears weeks or months after they are used, although some patients are struck years later. the predominant symptoms are increased awareness of lenses, ocular itching, blurred vision a...

جوادیان, احمد ,

In view of the rapid expansion of contact lens amongst the users, new dimensions have been added to the domain of ophthalmology: Giant papillay conjunctivitis, a disease caused by different kinds of contact lens, appears weeks or months after they are used, although some patients are struck years later. The predominant symptoms are increased awareness of lenses, ocular itching, blurred vision a...

Abbas Sheikhtaheri, Fatemeh Alipour, Fatemeh Falahati Marvast, Hossein Arabalibeik, Leila Nouri,

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

In this research work, a multibeam antenna which is a combination of a beamformer network (BFN) and a linear array antenna, has been designed. A Rotman lens has been chosen as beamformer network and Vivaldi antennas have been selected for constructing array antenna. The Substrate Integrated Waveguide (SIW) was used for implementing Rotman lens. After explanation the structure of Substrate integ...

Journal: :journal of current ophthalmology 0
حمید قرایی hamid gharaee محمدرضا صداقت mohammad reza sedaghat ملیحه نیک اندیش malihe nikandish

purpose: to evaluate visual function in patients with different types of light-filtering intraocular lenses (iols) methods: in this prospective comparative clinical study cataract patients with different types of iols in khatam-al-anbia eye hospital, mashhad were enrolled and followed for three months postoperatively. corrected distance visual acuity (cdva), color discrimination under photopic ...

طلایی خوزانی, طاهره, فاضل, علیرضا , عرب, محمدرضا ,

  Lens development requires precise interaction between cranial surface ectoderm, Neuroectoderm and interposed mesenchyme. Cell surface glycoconjugate and extracellular matrix govern lens morphogenesis. The aim of the present study was to investigate the presence and distribution of Glycoconjugate and extracellular matrix components.   Embryos from day 11-20 of gestation from whistar rat were c...

Journal: :بینا 0
محمد پاکروان m pakravan ophthalmic epidemiology research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی اعظم علوانی a alvani ophthalmic epidemiology research center, shahid beheshti university of medical sciences, tehran, iranشعبه بین الملل دانشگاه علوم پزشکی شهید بهشتی ابراهیم جعفرزاده پور e jafarzadehpoor ophthalmic epidemiology research center, shahid beheshti university of medical sciences, tehran, iranدانشکده توانبخشی- دانشگاه علوم پزشکی شهید بهشتی سیدمهدی طباطبایی sm tabatabaei shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی شاهین یزدانی sh yazdani ophthalmic epidemiology research center, shahid beheshti university of medical sciences, tehran, iranمرکز تحقیقات مهندسی بافت چشم- دانشگاه علوم پزشکی شهید بهشتی مهدی یاسری m yaseri دانشکده بهداشت و آمار- دانشگاه علوم پزشکی تهران

purpose: to describe the biometric changes and their effect on intraocular lens (iol) power calculation after trabeculectomy and to compare the accuracy of four formulas namely srk/ii, srk/t, holladay and hoffer q for iol power calculation in these patients. methods: thirty-four eyes of 31 glaucoma patients who were scheduled for primary trabeculectomy were enrolled. a non-contact biometry devi...

Journal: :بینا 0
سیدجواد هاشمیان sj hashemian iran university of medical sciences, tehrدانشگاه علوم پزشکی ایران an, iranدانشگاه علوم پزشکی ایران محمد سلیمانی m soleimani مرکز تحقیقات چشم- دانشگاه علوم پزشکی تهران علیرضا فروتن ar foroutan iran university of medical sciences, tehran, iranدانشگاه علوم پزشکی ایران محمود جوشقانی m joshaghani iran university of medical sciences, tehran, iranدانشگاه علوم پزشکی ایران محمدجعفر قائم پناه mj ghaempanah iran university of medical sciences, tehran, iranدانشگاه علوم پزشکی ایران نرگس حسن پور n hassanpoor دانشگاه علوم پزشکی تهران محمدابراهیم جعفری

purpose: to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (piol) implantation to correct myopia and myopic astigmatism in keratoconus-affected patients. methods: uncorrected (ucva) and best-corrected (bcva) distance visual acuity, refraction and complications were evaluated in 22 keratoconic eyes of 14 patients who un...

Journal: :بینا 0
فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی علیرضا برادران رفیعی a baradaran rafii ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی جواد هاشمیان j hashemian tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران علی هاشملو a hashemloo ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی ابراهیم جعفری e jafari tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران مهدی یاسری m yaseri ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranگروه بهداشت و آمار حیاتی- دانشگاه علوم پزشکی تهران

purpose: to compare visual outcomes and surgical complications of three phakic intraocular lenses (piols); artisan, artiflex and the implantable collamer lens (icl) for correction of moderate to high myopia. methods: in this historical cohort study, 112 myopic eyes that were operated between 2005 and 2010 and implanted with one of these three piols were evaluated (artisan 40 eyes, artiflex 36 e...

Journal: :international journal of preventive medicine 0
hasan razmjoo elham abdi sayna atashkadi mohamad reza akhlaghi ali reza peyman mojtaba akbari

background: silicon hydrogel bandage contact lenses are used to enhance epithelial healing, control surface-generated pain, and prevent epithelial erosions after refractive surgery. considering the importance of faster reepithelialization in preventing complications of photorefractive keratectomy (prk) and the fact that the features and specifications of these commercially-available lenses are ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید