نتایج جستجو برای: latex gloves

تعداد نتایج: 14343  

Journal: :international journal of occupational hygiene 0
teimour allahyari department of occupational health, faculty of health, urmia university of medical sciences,iran. farin khanehshenas department of occupational health, faculty of health, urmia university of medical sciences,iran. hamidreza khalkhali department of statistics, faculty of health, urmia university of medical sciences,iran.

the present study was conducted to examine the effect of using latex and nitrile examination gloves on hand dexterity.  a  sample  consisting  of  30  university  students  from  urmia  university  of  medical  sciences participated in this study in 2013. the participants conducted purdue pegboard test in three experimental conditions: bare hand (control), with latex gloves and with nitrile glo...

Journal: :acta medica iranica 0
gh. pouryaghoub r. mehrdad m. m. mazhari

latex allergy has become an occupational hazard among healthcare workers. atopy, intensity and duration of exposure have been recognized as predisposing factors for latex sensitization. frequency of sensitization varies among countries. so we decided to investigate the prevalence of latex sensitization and potential risk factors among healthcare workers in a general hospital. in a cross section...

الهیاری, تیمور , خانه شناس, فرین , خلخالی, حمید رضا ,

Introduction: Manual dexterity impairment due to wearing latex and nitrile gloves among health care employees and laboratory personnel can be a remarkable problem because of its adverse outcomes. The present study was conducted to “compare the effect of using latex and nitrile laboratory gloves on hand dexterity”. .Material and Method: In a semi experimental study design, 30 university were s...

2016
Mustafa Kayan Selçuk Yaşar Mustafa Saygın Ömer Yılmaz Aykut Recep Aktaş Fatmanur Kayan Yasin Türker Gürsel Çetinkaya

OBJECTIVE We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. METHODS The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL),...

Journal: :Occupational Medicine 1999

Journal: :avicenna journal of dental research 0
n gholizadeh assistant professor, department of oral medicine, faculty of dentistry, tabriz university of medical sciences,, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی تبریز (tabriz university of medical sciences) h khoeini poorfar assistant professor, department of oral medicine, faculty of dentistry, tabriz university of medical sciences,, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی تبریز (tabriz university of medical sciences) m mehdipour associate professor, department of oral medicine, faculty of dentistry, tabriz university of medical sciences,سازمان اصلی تایید شده: دانشگاه علوم پزشکی تبریز (tabriz university of medical sciences) m johari assistant professor, department of oral radiology, faculty of dentistry, tabriz university of medical sciences, , iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی تبریز (tabriz university of medical sciences) y rashidi dentist h jabbari khamnei assistant professor, department of statistics, faculty of mathematical sciences, , iranسازمان اصلی تایید شده: دانشگاه تبریز (tabriz university)

statement of the problem dental gloves are worn to protect dental care providers from contamination during contact with mucus membranes, blood and saliva. the prevalence of latex allergy has progressively increased due to the widespread use of protective disposable wears, especially latex gloves, among health care workers (hcw) in the past decade. the prevalence of latex allergy among hcw of ir...

Journal: :The Journal of allergy and clinical immunology 2004
Hoong-Yeet Yeang Siti Arija M Arif Monika Raulf-Heimsoth Yin-Ho Loke Ingrid Sander Siti Hawa Sulong Chee-Heng Lau Robert G Hamilton

BACKGROUND Sensitization to natural rubber latex has been linked to proteins from medical latex gloves. Various assays to estimate the amount of residual allergenic proteins extractable from latex gloves to assess their potential exposure hazard have inherent weaknesses. OBJECTIVE This investigation was aimed at developing 2-site immunoenzymetric assays and identifying appropriate protein mar...

Journal: :Contact dermatitis 2012
Denis Sasseville Mimi Thériault

Allergy to natural rubber latex (NRL) gloves in healthcare workers is well recognized, and usually presents as immunological contact urticaria and sometimes anaphylaxis. Latex gloves can also cause allergic contact dermatitis, mostly because of rubber accelerators. As latex sensitivity is well known in healthcare settings, synthetic latex-free gloves are widely used. The most popular latexfree ...

A Kazemnejad A Kouhkan AR Zarinara B Rajabi Gh.A Kardar M Heidar Zadeh M Mesdaghi Sh Shahabi Z Pourpak

Background: Latex allergy is a major occupational disease with prevalence nearly 5-17% among the health care workers. Objective: To determine the prevalence of latex glove allergy and its contributing factors among operation room staff. Patients and Methods: In this study, 512 operation room staff were evaluated for latex allergy, using a complete questionnaire. Those suspected to have latex al...

2014
Timothy F. Landers Anthony Dent Abhishek Deshpande

The objective of this study was to explore the utility of nitrile gloves as a replacement for latex surgical gloves in recovering bacteria from the hands. Two types of nitrile gloves were compared to latex gloves using the parallel streak method. Streaks of Klebsiella pneumoniae and Staphylococcus aureus were made on tryptic soy agar plates, and the zones of inhibition were measured around piec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید