نتایج جستجو برای: ionselective electrode

تعداد نتایج: 64456  

Journal: :iranian journal of pharmaceutical sciences 0
nahla sayed ismail nodcar

abstract the utility of carbon paste electrode for the determination of flavoxate hcl modified with flavoxate-tetraphenylborate (flx-tpb) and flavoxate-phosphotungestic acid (flx-pta) ion-pairs in batch mode is demonstrated. the electrodes revealed a nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol l-1 and1×10-5-1x10-2 mol l-1 using flx-tpb and flx-pta, respectively. the...

2006
P. T. BRAY G. C. F. CLARK G. J. MOODY

Screening of sweat chloride in newborn infants with the Orion Skin Chloride Measuring System and incorporating some procedural innovations is described. The results indicate that while diagnostic screening for cystic fibrosis can be readily undertaken, the test with the chloride ionselective electrode is best left at least to the second day of life or later because of insufficient sweating in v...

Journal: :Вестник Тверского государственного университета. Серия: Химия 2020

2001
Chang Wei Geza Nagy Klara Toth

Electrodes for scanning ion-selective potentiometric microscopy (or potentiometric SECM) were developed and used to image local concentration profiles of NH4+, K+, and Zn2' ions. Neutral carrier-based micropipet ionselective electrodes with high spatial resolution (-2-3 pm) and fast response time (-300 ms) were fabricated and employed as potentiometric SECM tips, and highresolution ion-selectiv...

2012
Emanuel Šucman Jiří BEdnář

Šucman E., Bednář J. (2012): Determination of fluoride in plant material using microwave induced oxygen combustion. Czech J. Food Sci., 30: 438–441. Fluorine is essential in human and/or animal nutrition, thus it is important to know its concentration in a diet. One of the important sources of fluorine for humans is tea, containing relatively high amounts of this trace element. A method for flu...

Journal: :The Journal of Automatic Chemistry 1990
Joan Farré Carmen Biosca Román Galimany

The Jokoo-ION 150 AC is an automatic sodium, potassium and chloride analyser which uses ion-selective electrodes.The sample mode can be whole-blood, serum or urine. To evaluate a urine sample, a previous dilution (1:6) with the standard 1 solution is required. For three concentrations of control materials, the total precision (CV) ranged from 0.17 to 1.22% for sodium, 0.22 to 1.69% for potassiu...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

2004
Urs Oesch Daniel Ammann Wilhelm Simon

Among the techniques of detection used in clinical chemistry, optical and electrochemical methods are especially attractive. However, except for glass electrodes for pH measurement, potentiometric electrochemical sensors (ionselective electrodes) gained general acceptance in clinical analyzers and in clinical instrumentation, respectively, only around 1970 (for reviews see 1-5). Here we report ...

2012
Kevin J. Sibley Gordon R. Brewster Tessema Astatkie John F. Adsett Paul C. Struik

Standard laboratory methods for measurement of soil nitrate (NO3–N) use various procedures and instruments to analyze soil samples taken from the field and transported to the laboratory. Concerns with these procedures range from delays in measurement time, the high cost of soil sampling and analysis, high labour requirements, and the need to aggregate samples. With recent advances in using the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید