نتایج جستجو برای: ion trap

تعداد نتایج: 229696  

جانی‌پور شهرود کلایی, قاسم , نوشاد, هوشیار ,

 The behavior of ions in a Paul trap has been investigated using numerical solution of the set of Mathieus differential equations. Afterwards, the trajectories of two typical ions such as H+ and 208Pb+ in the trap have been obtained using the fourth-order Runge-Kutta method. For specific dimensions of a Paul trap and a given frequency, the stability regions for separation of H+ and 2H+ ions hav...

Journal: :Quantum Information & Computation 2002
M. A. Rowej Amit Ben-Kish Brian Demarco Dietrich Leibfried Volker Meyer Jim Beall Joe Britton J. Hughes Wayne M. Itano Brana Jelenkovic Chris Langer Till Rosenband David J. Wineland

We have investigated ion dynamics associated with a dual linear ion trap where ions can be stored in and moved between two distinct locations. Such a trap is a building block for a system to engineer arbitrary quantum states of ion ensembles. Specifically, this trap is the unit cell in a strategy for scalable quantum computing using a series of interconnected ion traps. We have transferred an i...

2005
S. D. Bergeson

We report an optical dipole trap for calcium. The trap is created by focusing a 488-nm argon-ion laser beam into a calcium magneto-optical trap. The argon-ion laser photoionizes atoms in the trap because of a nearresonance with the 4s4f F3 level. By measuring the dipole-trap decay rate as a function of argon-ion laser intensity, we determine the F3 photoionization cross section at our wavelengt...

2009
Jesper V. Olsen Jae C. Schwartz Jens Griep-Raming Michael L. Nielsen Eugen Damoc Eduard Denisov Oliver Lange Philip Remes Dennis Taylor Maurizio Splendore Eloy R. Wouters Michael Senko Alexander Makarov Matthias Mann Stevan Horning

Since its introduction a few years ago, the linear ion trap Orbitrap (LTQ Orbitrap) instrument has become a powerful tool in proteomics research. For high resolution mass spectrometry measurements ions are accumulated in the linear ion trap and passed on to the Orbitrap analyzer. Simultaneously with acquisition of this signal, the major peaks are isolated in turn, fragmented and recorded at hig...

2009
G. Eitel D. Rodríguez C. Smorra K. Blaum

A commercial, position-sensitive ion detector was used for the rst time for the time-ofight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from ...

2011
S. Seddighi Chaharborj Yousof Gheisari

The purpose of this article is the comparison of a cylindrical ion trap supplied by a periodic impulsional potential with quadrupole ion trap. To compute the five stability regions for the cylindrical ion trap (CIT) and quadrupole ion trap (QIT) in the a − q plane we use the RungeKutta method with the fifth order derivative approximations. The first up to five stability regions obtained in this...

2016
A. Schuessler

2014 Ion confinement in an purely electrostatic ion trap is investigated. The trap consists of two concentric cylinders maintained at a potential difference and two electrically insulated end plates. If the length of the trap is long compared with the radial dimension of the trap, the radial potential distribution is practically logarithmic. The domain of ion confinement is derived by comparing...

Journal: :Physical review letters 2012
Marko Cetina Andrew T Grier Vladan Vuletić

We present, and derive analytic expressions for, a fundamental limit to the sympathetic cooling of ions in radio-frequency traps using cold atoms. The limit arises from the work done by the trap electric field during a long-range ion-atom collision and applies even to cooling by a zero-temperature atomic gas in a perfectly compensated trap. We conclude that in current experimental implementatio...

2014
C. Andreoiu J. Dilling D. Frekers

A novel in-trap decay spectroscopy facility has been developed and constructed for use with TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN). This apparatus consists of an open-access spectroscopy ion-trap, which is surrounded radially with up to seven low-energy planar Si(Li) detectors. The ion-trap environment allows for the detection of low-energy photons by providing backing-free st...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید