نتایج جستجو برای: iodide ion
تعداد نتایج: 217976 فیلتر نتایج به سال:
an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
In this research work, ZnO nanotubes were fabricated on a gold coated glass substrate through chemical etching by the aqueous chemical growth method. For the first time a nanostructure-based iodide ion selective electrode was developed. The ZnO nanotubes were functionalized with miconazole ion exchanger and the electromotive force (EMF) was measured by the potentiometric method. The iodide ion ...
A new carbon paste electrode (CPE) for the determination of iodide ion based on a cetyltrimethylammonium iodide (CTMAI) ion pair as an electroactive material is described. The electrode shows a linear response for iodide ion over the concentration range of 4 x 10(-5) M to 1 x 10(-1) M with a lower detection limit of 4 x 10(-5) M at 25 degrees C. The electrode has a Nemstian slope of -55.0 +/- 0...
Sodium salt of chloride, bromide and iodide were used to elucidate the effect of the size of the anion on the binding to pharaonis halorhodopsin and its transport during the photocycle of this retinal protein. Spectroscopic titration revealed an apparent strong binding constant of 2 mM for chloride, 0.23 mM for bromide and 5 mM for iodide. In the case of iodide a second, week binding constant o...
The react ion rate of the cou lomet r ic variant of the Karl-Fischer t i t ra t ion reac t ion (in which electrolyt ical ly generated t r i iodide is used as ox idan t instead of iodine) has been measured in methanol . The react ion is first order in water , sulfur d ioxide and t r i iodide, respectively. For pH < 5 the react ion rate cons tan t decreases logari thmical ly wi th decreasing pH. ...
The effect of adding known amounts of bromide and iodide to a plasma pool an several methodologies for measuring chloride ion has been studied. Methods evaluated were coulometric, colorimetric, and ion-specific electrode. Three different types of electrodes were evaluated in order to assess any improvements which might have been made in recent years. The older electrode methodology showed an ex...
X-Ray scattering measurements of 2.78 and 5.56 molal aqueous solutions of caesium iodide and 2.78 and 6.05 molal lithium iodide were carried out at 293 and 343 K Differences in the radial distribution functions (DRDFs) have been obtained between the caesium iodide and lithium iodide solutions of similar composition, the latter being taken as a reference for the data analysis of the former. The ...
Rate constants for acid catalysis of the reactions of N-chlorodimethylamine (1), N-chloro-2,2,2-trifluoroethylamine (2) and N,N-dichlorotaurine (3) with iodide ion were determined in H(2)O at 25 degrees C and I = 0.5 (NaClO(4)). The failure to detect significant catalysis by general acids of chlorine transfer from 1 to the nucleophile, together with the observed inverse solvent deuterium isotop...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید