نتایج جستجو برای: intraocular lens power calculation formulas
تعداد نتایج: 670242 فیلتر نتایج به سال:
purpose: to describe the biometric changes and their effect on intraocular lens (iol) power calculation after trabeculectomy and to compare the accuracy of four formulas namely srk/ii, srk/t, holladay and hoffer q for iol power calculation in these patients. methods: thirty-four eyes of 31 glaucoma patients who were scheduled for primary trabeculectomy were enrolled. a non-contact biometry devi...
purpose: in the present study we have tried to find the most reliable intraocular lens (iol) power calculation formula in patients with keratoconus (kcn) and cataract. methods: in a prospective case series between october 2010 and march 2012, eligible patients with cataract and kcn underwent phacoemulsification with iol implantation. preoperatively, based on iol master keratometric data iol pow...
purpose: to evaluate ocular biometric changes after phacotrabeculectomy and its effect on intraocular lens power calculation. methods: twenty six eligible eyes (24 patients) underwent phacotrabeculectomy. they were reexamined at least 6 months after the operation in a historical cohort study. main outcome measures included axial length (al) with contact a- scan (us-8000, nidek, gamaguri, japan)...
Formulas For Intraocular lens Power calculatIon Modern cataract surgery replaces the natural lens of the eye with an intraocular lens (IOL). After surgery, the optical system of the eye will consist of two major refractive elements, the cornea and the newly inserted IOL. This two-lens system is at the basis of IOL power calculation. To facilitate calculations, both the cornea and the IOL are co...
Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...
Efficacy of intraocular lens power calculation formulas in a subset of Indian myopic population. Retrospectively reviewed 43 patients who underwent phacoemulsification with high axial length (AL) (>24.5 mm, range 24.75-32.35 mm). The power of the implanted intraocular lens (IOL) was used to calculate the predicted post-operative refractive error by four formulas: Sanders-Retzlaff-Kraff (SRK II)...
نمودار تعداد نتایج جستجو در هر سال