Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...
introduction intensity-modulated radiotherapy (imrt) is becoming an increasingly routine treatment method. imrt can be delivered by use of conventional multileaf collimators (mlcs) and/or physical compensators. one of the most important factors in selecting an appropriate imrt technique is integral dose. integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
introduction intensity modulated radiation therapy (imrt) has made a significant progress in radiation therapy centers in recent years. in this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. considering the complexity of this method, the quality control for imrt is a topic of interest for researchers. this article is about the various ...
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
مقدمه: این مطالعه، با هدف تعیین دز جذبی هیپوکامپ در پرتودرمانی گلیومای مغزی با درجه ی بالا با استفاده از روش نقاشی دز و مقایسه ی آن با روش های پرتودرمانی تطبیقی سه بعدی و پرتودرمانی با شدت تعدیل شده (intensity-modulated radiation therapy یا imrt) انجام شد. روش ها: مطالعه ی حاضر در بخش پرتودرمانی بیمارستان میلاد اصفهان انجام شد. تصاویر magnetic resonance imaging (mri) 24 بیمار مبتلا به تومور گلی...
Recently the compensator has been shown to be an in expensive and reliable dose delivery device for photon beam intensity-modulated radiation therapy (IMRT). The goal of IMRT compensator design is to produce an optimized primary fluence profile at the patient's surface obtained from the optimization procedure. In this paper some of the problems associated with IMRT compensator design, specifica...
When a brass compensator is set in a treatment beam, beam hardening may take place. This variation of the energy spectrum may affect the accuracy of dose calculation by a treatment planning system and the results of dose measurement of brass compensator intensity modulated radiation therapy (IMRT). In addition, when X-rays pass the compensator, scattered photons are generated within the compens...
مقدمه: در این مطالعه، مقایسه ای بین دز جذبی پاروتید و بافت حساس اطراف آن در انواع طراحی درمان های مختلف جهت دستیابی به تکنیک بهینه ی درمان انجام گردید. دز جذبی اعضای مختلف با استفاده از نرم افزار طراحی درمان اندازه گیری شد. روش ها: طراحی و انجام کانتورینگ بر روی اسکن 15 بیمار، با استفاده از نرم افزار tigrt صورت گرفت. 6 تکنیک مقایسه شدند. در نهایت، با مقایسه ی میانگین دز رسیده به هر عضو با استفا...