نتایج جستجو برای: infusion pump

تعداد نتایج: 117873  

Journal: :iranian journal of pharmaceutical research 0
f fahimi m sistanizad r abrishami s baniasadi

since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (icu). the investigation was conducted in a teaching hospital in the form of a prospective, observational study. a sample size of 43 doses administered to icu patients was chosen to enable reliable estimate of error ...

Journal: :journal of cellular and molecular anesthesia 0
behnam mahmoodiyeh arak university of medical science, anesthesiology and critical care department mohamad khalili arak university of medical science, anesthesiology and critical care department maryam panahi resident of anesthesiology, arak university of medical science, anesthesiology and critical care department esmaeel moshiri assistant professor, ,arak university of medical science, anesthesiology and critical care department sayed mehran marashian chronic respiratory diseases research center, national research institute of tuberculosis and lung diseases (nritld), shahid beheshti university of medical sciences, tehran, iran alireza jahangirifard lung transplantation research center, national research institute of tuberculosis and lung diseases (nritld), shahid beheshti university of medical sciences, tehran, iran

background: adjuvants such as ketamine, promethazine and paracetamol could bring up patients satisfaction and control harmful effects of opioids besides lessening their needed doses, as seen by fentanyl/paracetamol and fentanyl/ketamine combination before. the current study headed to compare paracetamol and ketamine in addition to fentanyl applied by infusion pumps in order to pain relief follo...

Journal: :anesthesiology and pain medicine 0
masood mohseni department of anesthesiology, rasoul akram medical center, iran university of medical sciences, tehran, iran amin ebneshahidi persia research center, isfahan, iran; persia research center, isfahan, iran. tel/fax: +98-3116683568

conclusions this study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. these laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia. results the mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not st...

Journal: :Journal of diabetes science and technology 2013
Luis G Jahn Jorge J Capurro Brian L Levy

BACKGROUND As all major insulin pump manufacturers comply with the international infusion pump standard EN 60601-2-24:1998, there may be a general assumption that all pumps are equal in insulin-delivery accuracy. This research investigates single-dose and averaged-dose accuracy of incremental basal deliveries for one patch model and three durable models of insulin pumps. METHOD For each pump ...

Arash Dehghan, Hanieh Hosseini, Hossein Esfahani, Sara Esfahani,

Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...

Journal: :Medical Journal Armed Forces India 2003

2016
Bongsu Jung Kwang-Suk Seo Suk Jin Kwon Kiyoung Lee Suyong Hong Hyounsoon Seo Gi-Young Kim Geun-Mook Park Juhee Jeong Soowon Seo

BACKGROUND In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be recei...

Journal: :iranian journal of blood and cancer 0
hossein esfahani arash dehghan hanieh hosseini sara esfahani

background: it is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. in the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. materials and methods: in this study 60 units of packed red cells were examined before and after pa...

2010
P L Trbovich S Pinkney J A Cafazzo A C Easty

OBJECTIVE Assess the impact of infusion pump technologies (traditional pump vs smart pump vs smart pump with barcode) on nurses' ability to safely administer intravenous medications. DESIGN Experimental study with a repeated measures design. SETTING High-fidelity simulated inpatient unit. RESULTS The nurses remedied 60% of "wrong drug" errors. This rate did not vary as a function of pump ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید