the resonant frequency and sensitivity of an atomic force microscope (afm) cantilever with assembled cantilever probe (acp) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. the proposed acp comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the afm capable of topography at sidew...
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
In dynamic plowing lithography, the sample surface is indented using a vibrating tip in tapping mode atomic force microscopy. During writing, the gap between the cantilever and the sample surface is very small, usually on the order of micrometers. High vibration frequency and small distance induce squeeze film air damping from the air in the gap. This damping can cause variations in the cantile...
Numerical modelling of atomic force microscopy cantilever designs and experiments is presented with the aim of exploring friction mechanisms at the microscale. As a starting point for this work, comparisons between finite element (FE) models and previously reported mathematical models for stiffness calibration of cantilevers (beam and V-shaped) are presented and discrepancies highlighted. A col...
background and aims. all-on-four technique involves the use of tilted implants to allow for shorter cantilevers. this finite element analysis aimed at investigating the amount and distribution of stress in maxillary bone surrounding the implants with all-on-four vs. frequently used method with six implants technique using different numbers and inclination angles. materials and methods. a 3d ede...
Background and aims. All-on-four technique involves the use of tilted implants to allow for shorter cantilevers. This finite element analysis aimed at investigating the amount and distribution of stress in maxillary bone surrounding the implants with all-on-four vs. frequently used method with six implants technique using different numbers and inclination angles. Materials and methods. A 3D ede...