نتایج جستجو برای: implantable defibrillators

تعداد نتایج: 19632  

Journal: :the journal of tehran university heart center 0
maryam moshkani farahani atherosclerosis research center, baqiyatallah university of medical sciences, tehran, iran. mehrdad taghipour nephrology and urology research center, baqiyatallah university of medical sciences, tehran, iran. mohsen motalebi nephrology and urology research center, baqiyatallah university of medical sciences, tehran, iran. ramezan bakhshian atherosclerosis research center, baqiyatallah university of medical sciences, tehran, iran. ehsan shahverdi student research committee, baqiyatallah university of medical sciences, tehran, iran. sovaid taghipour islamic azad university, babol branch, babol, iran.

background: psychological problems such as depression constitute a dilemma that patients with the implantable cardioverter-defibrillator (icd) usually encounter and may impact their quality of life. the purpose of this study was to evaluate the prevalence of depression among adults with the icd and the relationship between depression and associated factors.    methods: totally, 115 individuals ...

Journal: :bulletin of emergency and trauma 0
fatemeh ranjbar dep. of psychiatry, tabriz university of medical sciences,tabriz, iran fariborz akbarzadeh babak kazemi abdolmohammad ranjbar sonia sharifi namin homayoun sadeghi-bazargani

objective: to determine the type and pattern of arrhythmic events following the 2012 ahar-varzegan earthquake among patients implanted with cardiac defibrillators (icds) in east azarbaijan province. methods: in a prospective cohort study, conducted in east azerbaijan province of iran, 132 patients were enrolled in two comparison groups according to the region of residence i.e., earthquake regio...

Journal: :journal of research in medical sciences 0
mohsen mir mohammad sadeghi akbar sadri departments of cardiac surgery, chamran hospital, isfahan university of medical sciences, isfahan, iran ahmad mirdamadi islamic azad university, najafabad branch, medical school, isfahan, iran mohammad reza samiee nasab department of cardiology, chamran hospital, isfahan university of medical sciences, isfahan, iran elham majidi department of cardiac surgery, sina hospital, isfahan university of medical sciences, isfahan, iran pouya mir mohammad sadeghi medical students' research committee, isfahan university of medical sciences, iran

the usage of implantable cardiac defibrillator (icd) since 1980s is becoming more popular these days. the rate of both, endocarditis and constrictive pericarditis are low but it still needs attention. we are reporting a rare case of icd endocarditis as a result of toe infection in a diabetic patient. this was followed by infectious pericarditis after device removal by open heart surgery and the...

2014
A F Deroee B J Cohen J F O'Hara

  Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...

Journal: :Journal of the American Heart Association 2016
Christine I Nichols Joshua G Vose Suneet Mittal

BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...

2014
Teri M. Kozik Gianna Chien Therese F. Connolly Gurinder S. Grewal David Liang Walter Chien

BACKGROUND Over 140 million iPads(®) have been sold worldwide. The iPad2(®), with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life-threatening situations in patients. The goal of this study was to determine whether the iPad2(®) can cause ...

Journal: :The Kobe journal of medical sciences 2016
Nao Saito Chiemi Taru Ikuko Miyawaki

This prospective study clarified changes in the mood states of Japanese patients with implantable cardioverter defibrillators as well as factors related to the mood states. Using a longitudinal repeated-measure design, 29 patients with implantable cardioverter defibrillators completed the Profile of Mood States-Short Form Japanese Version questionnaire before discharge and 1, 4, 7, and 13 month...

Farshad Farshidfar Hayedeh Ghaninejadi Roghie Shamsoddini Soheil Fateh,

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

Journal: :European heart journal 2001
J A Chiladakis P Davlouros G Agelopoulos A S Manolis

AIMS To investigate the susceptibility of implantable cardioverter defibrillators to electromagnetic interference generated by digital cellular telephones, functioning in both international transmission technologies: the Global System for Mobile Communication (GSM) and the Digital Cellular System (DCS 1800). METHODS AND RESULTS In 36 patients with transvenous implantable cardioverter defibril...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید